🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB Miniature Circuit Breaker - SB200M I - 4P - D10 A - D · 1SYS274022R01011SYS274022R0101↓ 53% off MRP
BrandABB
CategorySwitchgear
SpecificationSB204M I-D10 · System Pro M
Brand SKU1SYS274022R0101
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB Miniature Circuit Breaker - SB200M I - 4P - D10 A - D · 1SYS274022R0101

NEW added this week
₹2,086/pcincl. GST-53%
₹1,768 + 18% GST · MRP ₹4,421
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹2,086 /pc incl. GST
Free delivery over ₹4,000

ABB Miniature Circuit Breaker - SB200M I - 4P - D10 A - D · 1SYS274022R0101: Elume price today ₹2,086 per pc incl. GST, 53% below the ₹4,421 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹4,730₹4,033₹3,335₹2,638₹1,940₹4,421₹2,086
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹2,086
MRP
₹4,421
Lowest in view · 17 Nov
₹2,086
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹1,982/pc on this product, applied automatically

The MCB 10kA SB204M I-D10 provides overcurrent and short-cuicuit protection for industrial installations. This product is manufactured according to IEC Standards for the markets where it is required.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB Miniature Circuit Breaker - SB200M I - 4P - D10 A - D · 1SYS274022R0101 · 1SYS274022R0101
Device typeMiniature circuit breaker (MCB)
SeriesSystem Pro M
Reference standardIS/IEC 60947
Country of originIndia
Current rating10 A
Poles4-pole
BrandABB
Brand SKU1SYS274022R0101
ELINEJH7G274CR
Sold asPer pc
StandardsIS/IEC 60947
Package Width74 mm
Package Height82 mm
Package Length95 mm
Housing MaterialInsulation Group II, RAL 7035
Package Gross Weight0.455 kg
Extended Product TypeSB204M I-D10
Product RangeSystem Pro M
Ratings as published by ABB (shop.in.abb.com listing for 1SYS274022R0101, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.