Lauritz Knudsen AU MCB · 1P (SP) · 125 A · D curve · 15 kA · AU15S11253DAU15S11253D↓ 36% off MRP
BrandLauritz Knudsen
CategorySwitchgear
SpecificationMCB · 1P (SP) · 125 A · D curve · 15 kA · 240 V · IP20
Brand SKUAU15S11253D
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
Lauritz Knudsen· In stock
Visit the Lauritz Knudsen store

Lauritz Knudsen AU MCB · 1P (SP) · 125 A · D curve · 15 kA · AU15S11253D

Curve: D Curve
Current Rating: 125A
₹3,694/pcincl. GST-36%
₹3,131 + 18% GST · MRP ₹5,749
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹3,694 /pc incl. GST
Free delivery over ₹4,000

Lauritz Knudsen AU MCB · 1P (SP) · 125 A · D curve · 15 kA · AU15S11253D: Elume price today ₹3,694 per pc incl. GST, 36% below the ₹5,749 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
25 May to 22 Nov
₹6,151₹5,432₹4,712₹3,992₹3,272₹5,749₹3,694
May 26Jun 26Aug 26Sep 26Oct 26Nov 26Nov 26
Elume today
₹3,694
MRP
₹5,749
Lowest in view · 17 Aug
₹3,518
Highest in view · 3 Oct
₹3,694
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹3,509/pc on this product, applied automatically

Lauritz Knudsen AU MCB · 1P (SP) · 125 A · D curve · 15 kA is an MCB from Lauritz Knudsen. It protects a final circuit against overload and short circuit and is the standard outgoing device in a distribution board. Key ratings: Poles 1P (SP), Rated current 125 A, Trip curve D curve, Breaking capacity 15 kA, Rated voltage 240 V, Width 1.5 M. It is built to IS/IEC 60947-2, EN 60947-2.

  • True contact indication for each pole
  • Trip-free mechanism with current-limiting hammer trip
  • Label holder for circuit identification
  • Bi-connect terminals on both sides
As published by Lauritz Knudsen. Verify critical parameters against the datasheet before specifying.
Lauritz Knudsen Lauritz Knudsen AU MCB · 1P (SP) · 125 A · D curve · 15 kA · AU15S11253D · AU15S11253D
Device typeMiniature circuit breaker (MCB)
SeriesAU
Poles1P (SP)
Rated current125 A
Trip curveD curve
Breaking capacity15 kA
Rated voltage240 V
Width1.5 modules
Ingress protectionIP20
Reference standardIS/IEC 60947-2, EN 60947-2
Current rating125 A
BrandLauritz Knudsen
Brand SKUAU15S11253D
ELINERH76G73CJ
Sold asPer pc
Ratings as published by Lauritz Knudsen (Elume catalogue; Lauritz Knudsen smartshop; Lauritz Knudsen price list Aug 2026; Product name). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

What curve is this MCB?

The tripping curve of this MCB is D Curve. C is the general-purpose choice for mixed household loads, B suits lighting and resistive circuits, and D is for equipment with heavy inrush current.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.

No reviews yet