Schneider Schneider Easy TeSys LC1E Power Contactor · 3P · 40 A AC-3 · 1 NO aux · 220 V AC coil · LC1E40B10M7
Poles3P
Rated current40 A
Ingress protectionIP2X
Reference standardEN/IEC 60947-1
coil voltage220 V AC 50/60 Hz
Net weight0.45 kg
BrandSchneider
Brand SKULC1E40B10M7
ELINEPH74KFGH2
Sold asPer pc
RangeEasy TeSys
StandardsEN/IEC 60947-1 · EN/IEC 60947-4-1 · EN/IEC 60947-5-1 · GB/T 14048.1 · GB/T 14048.4 · GB/T 14048.5 · EN/IEC 60335-1:Clause 30.2 · EN/IEC 60335-2-40:Annex JJ · IS/IEC 60947-1 · IS/IEC 60947-4-1 · IS/IEC 60947-5-1
Motor power kW11 kW at 220/230 V AC · 18.5 kW at 380/400 V AC · 22 kW at 415/440 V AC 50/60 Hz · 22 kW at 500 V AC · 30 kW at 660/690 V AC · 18.5 kW at 440 V
Operating time12...22 ms on closing · 4...19 ms on opening
Heat dissipation2…3 W for control circuit
Mounting supportDIN rail · Plate
Non-overlap time1.5 ms on energisation guaranteed between NC and NO contact · 1.5 ms on de-energisation guaranteed between NC and NO contact
Pollution degree3
Range of productEasy TeSys Control
Average impedance2.5 mOhm - Ith 50 A 50 Hz for power circuit
Device short nameLC1E
Poles description3P
Tightening torqueControl circuit: 1.2 N.m · Power circuit: 2.1 N.m
Inrush power in VA95 VA 50 Hz cos phi 0.75 (at 20 °C) · 95 VA 60 Hz cos phi 0.75 (at 20 °C)
Operating altitude3000 m without derating
Control circuit typeAC at 50/60 Hz
Overvoltage categoryIII
Protective treatmentTH (pollution degree 3) conforming to IEC 60068
Utilisation categoryAC-3 · AC-3e · AC-1
Contactor applicationMotor control · Resistive load
Electrical durability350000 cycles AC-1 · 800000 cycles AC-3
Insulation resistance> 10 MOhm for auxiliary contact circuit
Mechanical durability5000000 cycles
Associated fuse rating63 A gG at <= 690 V coordination type 1 for power circuit · 10 A gG at <= 690 V for auxiliary contact circuit conforming to IEC 60947-5-1
Maximum operating rate1800 cyc/h 60 °C
Product certificationsCB Scheme · CCC · CE · EAC · BIS
Connections - terminalsPower circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible without cable end · Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible without cable end · Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible with cable end · Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: flexible with cable end · Power circuit:
IP degree of protectionIP2X conforming to IEC 60529
Rated breaking capacity340 A at 440 V for power circuit conforming to IEC 60947
Pole contact composition3 NO
Minimum switching current5 mA for auxiliary contact circuit
Minimum switching voltage17 V for auxiliary contact circuit
Product or component typeContactor
Irms rated making capacity520 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Power dissipation per pole2.9 W AC-3 · 5 W AC-1
[Uc] control circuit voltage220 V AC 50/60 Hz
Auxiliary contact composition1 NO
[Ui] rated insulation voltage690 V conforming to IEC 60947-4-1
Control circuit voltage limits0.85...1.1 Uc (-5…55 °C):operational 50/60 Hz · 0.3...0.6 Uc (-5…55 °C):drop-out 50/60 Hz
[Ie] rated operational current40 A (at <55 °C) at <= 440 V AC AC-3 for power circuit · 40 A (at <55 °C) at <= 440 V AC AC-3e for power circuit · 50 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
[Ue] rated operational voltagePower circuit: <= 690 V AC 50/60 Hz
Hold-in power consumption in VA8.5 VA 50 Hz cos phi 0.3 (at 20 °C) · 8.5 VA 60 Hz cos phi 0.3 (at 20 °C)
[Uimp] rated impulse withstand voltage6 kV coil not connected to the power circuit conforming to IEC 60947
[Icw] rated short-time withstand current320 A 40 °C - 10 s for power circuit · 165 A 40 °C - 60 s for power circuit · 72 A 40 °C - 600 s for power circuit
Permissible ambient air temperature around the device-20…70 °C at Uc · -60…80 °C storage · -5…55 °C operation
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.