🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Legrand CTX³ 3 Pole Contactor · 185 A AC-3 · 230 A AC-1 · Coil 48 V~/= · 2 NO + 2 NC · 416282416282↓ 26% off MRP
BrandLegrand
CategorySwitchgear
Specification185 A AC-3 · 230 A AC-1 · Coil 48 V~/= · 2 NO + 2 NC
Brand SKU416282
AvailabilityOn order · 2 to 3 weeks
DeliveryPan-India · 2 to 3 weeks
Legrand· On order, 2 to 3 weeks
Visit the Legrand store

Legrand CTX³ 3 Pole Contactor · 185 A AC-3 · 230 A AC-1 · Coil 48 V~/= · 2 NO + 2 NC · 416282

NEW added this week
₹41,640/pcincl. GST-26%
₹35,288 + 18% GST · MRP ₹56,270
Add to cart
Buy now
On order: delivered in 2 to 3 weeks. We order it from Legrand for you once you place the order.
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹41,640 /pc incl. GST
Delivery ₹1,000, ships insured

Legrand CTX³ 3 Pole Contactor · 185 A AC-3 · 230 A AC-1 · Coil 48 V~/= · 2 NO + 2 NC · 416282: Elume price today ₹41,640 per pc incl. GST, 26% below the ₹56,270 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹60,209₹54,838₹49,467₹44,096₹38,725₹56,270₹41,640
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹41,640
MRP
₹56,270
Lowest in view · 17 Nov
₹41,640
For panel builders
Buying this for a panel?
The price above is for a single piece. Send the whole BOM in any file and a person quotes the job within 24 hours.
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹39,558/pc on this product, applied automatically

Rating 185A (AC-3) for the switching of 3-ph motors up to 90 kW (415V). Resistive loads up to 230A (AC-1).

  • 2NO + 2NC auxiliary contacts. NC auxiliary contact meets the definition of mirror contact according to IEC 60947-4-1 standard. Can be equipped with all Legrand CTX3 auxiliaries and accessories.
  • Screw terminals capacity: Power 50mm² to 95mm² / Coil 1,25mm² to 5,5mm² / Aux. Circuit 1,25mm² to 5,5mm²
  • Endurance: up to 5 million mechanical operations and 1 million electrical operations. Number of operation cycles (AC-3) per hour : 1200.
As published by Legrand. Verify critical parameters against the datasheet before specifying.
Legrand Legrand CTX³ 3 Pole Contactor · 185 A AC-3 · 230 A AC-1 · Coil 48 V~/= · 2 NO + 2 NC · 416282 · 416282
SeriesCTX³
Operational current (Ie)185 A (AC-3)
Reference standardIEC 60947-4-1
Warranty18 months from the date of shipment or 12 months from the date of installation
Country of originSouth Korea
Power90 kW
Auxiliary contacts2 NO + 2 NC
Coil / control supply48 V AC
Device typeMiniature circuit breaker (MCB)
Current rating185 A
BrandLegrand
Brand SKU416282
ELINEPGRC2PK6H
Sold asPer pc
Ratings as published by Legrand (legrand.co.in; price list). Verify critical parameters against the datasheet before specifying.
Other Legrand ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.

No reviews yet