🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Out of stock · in stock hereOrient · Eurotech RCCB Double Pole · 30 mA · 40 A₹3,010₹3,835
Orient Eurotech RCCB Four Pole · 100 mA · 40 A201FA10040↓ 22% off MRP
BrandOrient
CategorySwitchgear
Specification40 A · 4P
Brand SKU201FA10040
AvailabilityOut of stock
DeliveryPan-India · 7 working days
Orient· Out of stock
Visit the Orient store

Orient Eurotech RCCB Four Pole · 100 mA · 40 A

Rating: 40A
struck through = out of stock
Sensitivity: 100mA
struck through = out of stock
₹3,751/pcincl. GST-22%
₹3,179 + 18% GST · MRP ₹4,780
Out of stock
This one cannot be ordered right now. These match its specification and are in stock:
Same specificationRCCB · 4P / 3P+N (three phase) · 40 A · 100 mA
OrientSame product
Eurotech RCCB Double Pole · 30 mA · 40 A
₹3,010incl. GST/pc-22%
MRP ₹3,835
HavellsIn stock
FP RCCB EURO2 D7 · 40 A · 100 mA · DHRACMFF100040
₹3,080incl. GST/pc-41%
MRP ₹5,184
Compare all 13 in-stock alternatives ↓
Need this exact model? Email info@elumenuvo.com and we will source it for you.
💳 30 Day credit facility available launching soon - join waitlist.

Orient Eurotech RCCB Four Pole · 100 mA · 40 A: Elume price today ₹3,751 per pc incl. GST, 22% below the ₹4,780 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
24 Aug to 22 Nov
₹5,370₹4,900₹4,429₹3,959₹3,488₹4,780₹3,751
24 Aug11 Sep29 Sep17 Oct4 Nov22 Nov
Elume today
₹3,751
MRP
₹4,780
Lowest in view · 22 Sep
₹3,751
Highest in view · 3 Oct
₹3,939
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCCB
4P / 3P+N (three phase)
40 A
n/a
100 mA
₹3,179 +GST /pc
₹3,751 incl. GST
Viewing above ↑
RCCB · Type AC
4P / 3P+N (three phase)
40 A
n/a
100 mA
₹1,922 +GST /pc
₹2,268 incl. GST
RCCB · Type AC
4P / 3P+N (three phase)
40 A
n/a
100 mA
₹2,358 +GST /pc
₹2,783 incl. GST
RCCB · Type AC
4P / 3P+N (three phase)
40 A
n/a
100 mA
₹2,610 +GST /pc
₹3,080 incl. GST
RCCB · Type AC
4P / 3P+N (three phase)
40 A
n/a
100 mA
₹2,692 +GST /pc
₹3,177 incl. GST
RCCB
4P / 3P+N (three phase)
40 A
n/a
100 mA
₹3,424 +GST /pc
₹4,040 incl. GST
RCCB
4P / 3P+N (three phase)
40 A
n/a
100 mA
₹3,527 +GST /pc
₹4,162 incl. GST
RCCB · Type AC
4P / 3P+N (three phase)
40 A
n/a
100 mA
₹3,584 +GST /pc
₹4,229 incl. GST
RCCB · Type AC
4P / 3P+N (three phase)
40 A
n/a
100 mA
₹4,854 +GST /pc
₹5,728 incl. GST
RCCB
4P / 3P+N (three phase)
40 A
n/a
100 mA
₹5,265 +GST /pc
₹6,213 incl. GST
RCCB · Type A
4P / 3P+N (three phase)
40 A
n/a
100 mA
₹5,791 +GST /pc
₹6,833 incl. GST
RCCB · Type AC
4P / 3P+N (three phase)
40 A
n/a
100 mA
₹6,267 +GST /pc
₹7,395 incl. GST
RCCB · Type A
4P / 3P+N (three phase)
40 A
n/a
100 mA
₹7,267 +GST /pc
₹8,575 incl. GST
RCCB · Type A
4P / 3P+N (three phase)
40 A
n/a
100 mA
₹9,321 +GST /pc
₹10,999 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹3,563/pc on this product, applied automatically

Bi-Directional Connection Terminal- Ensures easy and reliable connection from both line and load sides. Advanced Air Circulation Channels- Designed for efficient heat dissipation and enhanced performance. Easy Dismantling Mechanism- Provides convenient installation and maintenance. Positive Flag Indication- Clear visual indication for ON/OFF or trip status. Pad Locking Provision- Enables secure locking for added operational safety. Protective Terminal Covers- Enhances user safety by preventing accidental contact. SDB Technology- Integrated advanced technology for improved operational reliability. Overheat Sensing Technology- Detects abnormal temperature rise for enhanced protection. No Manual Thermal Bi-Metal Adjustment Required- Factory-calibrated design ensures consistent performance and reliability. Reduced Welding Joints- Improves product durability and electrical efficiency. Enhanced Arc Quenching System- Provides faster and safer arc suppression during operation. Line-Load Reversibility- Allows flexible installation from either side. Easy DIN Rail Clipping- Ensures quick and hassle-free mounting. Low Power Consumption- Optimized design for improved energy efficiency. 35 mm² Cable Terminal Capacity- Supports larger cable sizes for better connectivity. RoHS Compliant- Manufactured in accordance with environmental safety standards. IP20 Protection- Provides protection against accidental finger contact with live parts.

As published by Orient. Verify critical parameters against the datasheet before specifying.
Orient Orient Eurotech RCCB Four Pole · 100 mA · 40 A · 201FA10040
Poles4P (FP)
Rated current40 A
Sensitivity (IΔn)100 mA
Device typeResidual current circuit breaker (RCCB)
Current rating40 A
Sensitivity100 mA
Reference standardIS 12640-1 / IEC 61008
BrandOrient
Brand SKU201FA10040
ELINEMD2K3K6H4
Sold asPer pc
Ratings as published by Orient (orientelectric.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Is 30mA or 100mA RCCB right for home?

For protecting people from shock, use 30mA on circuits feeding sockets, bathrooms, kitchens and outdoor points. 100mA or 300mA RCCBs are mainly for fire protection and are often used upstream as a main device, with 30mA protection on the final circuits.

What sensitivity is this RCCB?

This RCCB trips at a residual (leakage) current of 100mA. 30mA is the standard for personal shock protection, while 100mA and 300mA are used for equipment and fire protection.

Does an RCCB need an MCB with it?

Yes. An RCCB only detects earth leakage and does not protect against overload or short circuit, so it must be backed up by an MCB or fuse of a rating given in the manufacturer's data (RCCBs are covered by IS 12640 (Part 1)).

Why does my RCCB keep tripping?

Common causes are genuine leakage from a faulty appliance (often a geyser element, pump or washing machine), moisture in wiring, neutral of one circuit being shared with another, or many electronic loads adding up their small leakages. Switch off all MCBs and turn them on one by one to find the culprit circuit, and have an electrician test insulation; never bypass the RCCB.

What is the difference between Type AC and Type A RCCB?

Type AC detects only sinusoidal AC leakage, while Type A also detects pulsating DC leakage produced by electronic loads like inverter ACs, washing machines, induction cooktops and LED drivers. Type A is the safer choice for modern homes with many electronic appliances; EV chargers and VFDs may need Type B or a charger with built-in DC detection.

How often should I press the test button?

Manufacturers commonly recommend pressing the test button regularly, often once a month; check the interval in the product's instructions. The RCCB should trip immediately, and if it does not, have an electrician check and replace it.

What current rating RCCB do I need - 25A, 40A or 63A?

The RCCB's rated current should be equal to or higher than the MCB or main switch feeding it, because it must carry the full load current. Many Indian homes use 40A or 63A RCCBs at the incomer; for a single circuit, 25A is common.

No reviews yet