🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Legrand DX3 RCBO · 2P (DP) · 40 A · 100 mA · 411334411334↓ 26% off MRP1 / 3
BrandLegrand
CategorySwitchgear
SpecificationResidual current breaker with overload protection · 2P (DP) · 40 A · 100 mA
Brand SKU411334
AvailabilityReady to ship · Only 2 left · Ships tomorrow
DeliveryPan-India · 5 working days
Legrand· Ready to ship
Visit the Legrand store

Legrand DX3 RCBO · 2P (DP) · 40 A · 100 mA · 411334

₹6,993/pcincl. GST-26%
₹5,926 + 18% GST · MRP ₹9,511
Add to cart
Buy now
Ready to shipOnly 2 left
Ships tomorrow. Delivery by Sat, 28 Nov.
In Delhi NCR? Get it today. Order before 1 pm for delivery the same day, after that the next day, for ₹400 extra. Choose Delhi NCR express at checkout.
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹6,993 /pc incl. GST
Free pan-India delivery

Legrand DX3 RCBO · 2P (DP) · 40 A · 100 mA · 411334: Elume price today ₹6,993 per pc incl. GST, 26% below the ₹9,511 MRP. The price has held steady for the last 30 days. The average price across the sellers we track is ₹5,651, ₹1,342 less than here.

Price history
Elume price vs the average market price across the sellers we track, day by day. Tap a legend entry to show or hide a line.
24 Aug to 22 Nov
₹12,721₹10,842₹8,962₹7,082₹5,202₹9,511₹6,993₹5,651
24 Aug11 Sep29 Sep17 Oct4 Nov22 Nov
Elume today
₹6,993
Avg market price
₹5,651
MRP
₹9,511
Lowest in view · 7 Oct
₹5,594
Highest in view · 23 Oct
₹6,993
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCBO
2P / 1P+N (single phase)
40 A
-
100 mA
₹5,926 +GST /pc
₹6,993 incl. GST
Viewing above ↑
RCBO · Type AC
2P / 1P+N (single phase)
40 A
-
100 mA
₹4,074 +GST /pc
₹4,807 incl. GST
RCBO · Type AC
2P / 1P+N (single phase)
40 A
C
100 mA
₹4,116 +GST /pc
₹4,857 incl. GST
RCBO · Type AC
2P / 1P+N (single phase)
40 A
C
100 mA
₹4,230 +GST /pc
₹4,991 incl. GST
RCBO · Type A
2P / 1P+N (single phase)
40 A
-
100 mA
₹4,434 +GST /pc
₹5,232 incl. GST
RCBO · Type AC
2P / 1P+N (single phase)
40 A
C
100 mA
₹4,708 +GST /pc
₹5,556 incl. GST
RCBO · Type A
2P / 1P+N (single phase)
40 A
C
100 mA
₹6,158 +GST /pc
₹7,267 incl. GST
RCBO · Type A
2P / 1P+N (single phase)
40 A
C
100 mA
₹8,992 +GST /pc
₹10,611 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹6,643/pc on this product, applied automatically

Legrand DX3-RCBO DP 40A 100MA

As published by Legrand. Verify critical parameters against the datasheet before specifying.
Legrand Legrand DX3 RCBO · 2P (DP) · 40 A · 100 mA · 411334 · 411334
Device typeResidual current breaker with overload protection (RCBO)
SeriesDX3
Poles2P (DP)
Rated current40 A
Sensitivity (IΔn)100 mA
Reference standardIS 12640
Warranty5 years if mounted inside Legrand DB
Country of originIndia
Current rating40 A
BrandLegrand
Brand SKU411334
ELINEDJ426J4PD
Sold asPer pc
Product Code411334
Product features➥ISI marked as per IS 12640-2➥Integrated label holder➥Ergonomic design➥Color coded On/Off indication on dolly➥Front face indication for earth leakage fault➥IP 20 protected terminals➥35 sq mm terminals➥Sliding shutters Integrated label holder IP 20 protected terminals 35 sq mm terminals Sliding shutters
Product Width (mm)99.5
Mechanism / AccessoriesMechanism
Ratings as published by Legrand (shop.legrand.co.in). Verify critical parameters against the datasheet before specifying.
Other Legrand ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
What is the difference between RCBO and RCCB?

An RCBO combines an MCB and an RCCB in one device, protecting a single circuit against overload, short circuit and earth leakage. An RCCB only handles earth leakage and needs separate MCBs (RCBOs are covered by IS 12640 (Part 2)).

Why use RCBOs instead of one main RCCB?

With RCBOs, a leakage fault on one circuit trips only that circuit, so the rest of the house keeps power and it is easier to find the fault. They cost more and take more DB space than one RCCB with several MCBs, so many homes use RCBOs only on critical circuits like geyser, washing machine and outdoor points.

Can I use an RCBO for my geyser or water pump?

Yes, an RCBO suits geysers, pumps and other loads in wet areas because it gives shock protection and overload protection on that one circuit. Choose the current rating and curve as you would for an MCB, based on the appliance's rated current and the cable, and have a licensed electrician confirm.

Does an RCBO need a neutral connection?

Yes. The RCBO compares phase and neutral current to detect leakage, so the circuit's neutral must pass through it and must not be shared with any other circuit.

Will an RCBO fit in a normal MCB distribution board?

RCBOs mount on the standard 35mm DIN rail, but many are 2 modules wide or need a separate neutral connection, so check that your DB has enough free ways and space. Some compact single-module RCBOs fit like an SP MCB; refer to the product's module width.

No reviews yet