Legrand Lyncus Modular MCB · 20 A · 1 M · White · 677282: Elume price today ₹392 per pc incl. GST, 34% below the ₹590 MRP. Today's price is the lowest of the last 30 days (high ₹393). The average price across the sellers we track is ₹317, ₹75 less than here. The lowest tracked seller lists it at ₹317, ₹75 below it (tell us and we match it).
The Lyncus range product with catalog number 677282 is a 20A Modular MCB SP 1M C Curve designed for overload and short circuit protection in electrical circuits. This single-pole miniature circuit breaker is compact, occupying just one module, and is suitable for both flush and surface-mounted installations. It features a sleek white color that blends seamlessly with modern interiors. The device is equipped with screw terminals, supporting wire capacities ranging from 1.5mm² to 6mm², and is compatible with flat-blade screwdrivers of 4mm to 5mm. Its dimensions include a width of 22.5mm, height of 45mm, and depth of 41mm, with a weight of 58 grams, ensuring ease of installation and handling. The MCB operates via a dolly (knob) mechanism and is constructed with high-quality materials such as nylon reinforced with 30% glass fiber for the dolly, PBT for the top and bottom covers, and brass with silver plating for the screws and terminals. Electrically, it is rated for 240V AC and 20A current, with a short circuit capacity of 1.5kA. The product is marked with essential details such as ratings, voltage, short circuit capacity, ON-OFF indication, connection diagram, manufacturing country,
Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.
The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.
A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.
Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.
Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.
No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.