Legrand DX³ Photovoltaic · DC MCB · 800 V= Circuit Breakers · Breaking capacity 4.5 kA · 13 A · 414427414427↓ 26% off MRP
BrandLegrand
CategorySwitchgear
SpecificationDC MCB · 800 V= Circuit Breakers · Breaking capacity 4.5 kA · 13 A
Brand SKU414427
AvailabilityOn order · 2 to 3 weeks
DeliveryPan-India · 2 to 3 weeks
Legrand· On order, 2 to 3 weeks
Visit the Legrand store

Legrand DX³ Photovoltaic · DC MCB · 800 V= Circuit Breakers · Breaking capacity 4.5 kA · 13 A · 414427

NEW added this week
₹6,832/pcincl. GST-26%
₹5,790 + 18% GST · MRP ₹9,232
Add to cart
Buy now
On order: delivered in 2 to 3 weeks. We order it from Legrand for you once you place the order.
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹6,832 /pc incl. GST
Free pan-India delivery

Legrand DX³ Photovoltaic · DC MCB · 800 V= Circuit Breakers · Breaking capacity 4.5 kA · 13 A · 414427: Elume price today ₹6,832 per pc incl. GST, 26% below the ₹9,232 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹9,878₹8,997₹8,116₹7,235₹6,354₹9,232₹6,832
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹6,832
MRP
₹9,232
Lowest in view · 17 Nov
₹6,832
For solar installers
Buying this for a rooftop solar job?
The price above is for a single piece. Send the whole requirement in any file and a person quotes the job within 24 hours.
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹6,490/pc on this product, applied automatically

Breaking capacity 4.5 kA according to EN 60947-2.

  • Integrated label holder➥Sliding bottom clamp➥Improved air channels➥Color coded On/Off indication on dolly➥Biconnect lower terminals➥IP 20 protected terminals➥Sliding shutters.
  • The DX DC circuit breaker is suitable for isolation.
  • No. of Modules: 4
  • Min. voltage: 12 V DC per pole
As published by Legrand. Verify critical parameters against the datasheet before specifying.
Legrand Legrand DX³ Photovoltaic · DC MCB · 800 V= Circuit Breakers · Breaking capacity 4.5 kA · 13 A · 414427 · 414427
SeriesDX³
Poles2P (DP)
Rated current13 A
Trip curveB curve
Ingress protectionIP20
Warranty5 years if mounted inside Legrand DB
Module size4 M
Device typeMiniature circuit breaker (MCB)
Current rating13 A
Breaking capacity4.5 kA
Reference standardIS/IEC 60898-1
BrandLegrand
Brand SKU414427
ELINE43CJ2RJK2
Sold asPer pc
Ratings as published by Legrand (legrand.co.in; price list). Verify critical parameters against the datasheet before specifying.
Other Legrand ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.