Havells X7 MCB TP · 20 A · DHMYCTPM020DHMYCTPM020↓ 41% off1 / 2
BrandHavells
CategorySwitchgear
SpecificationMCB · 3P (TP) · 20 A · C curve · 7.5 kA · 240 V
Brand SKUDHMYCTPM020
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Havells· In stock
Visit the Havells store

Havells X7 MCB TP · 20 A · DHMYCTPM020

Rating: 20 A
$14.40/pc-41%
$24.25
Wholesale · 15+ units
$14.11 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$14.40 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCB
TP
20 A
C
7.5 kA
$14.40 /pc
Viewing above ↑
MCB
TP
20 A
-
-
$20.69 /pc
MCB
TP
20 A
C
-
$26.63 /pc
MCB
TP
20 A
C
-
$34.72 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $14.11/pc on this product, applied automatically

63 A

  • Application : For industrial and commercial purposes
  • Rating : 6 A to 63 A
  • Specification : IS/IEC 60898-1 & IEC 60898-1
Air Circulation
When two poles are placed adjacent to each other, the channels between two poles form a tunnel resulting in very effective air circulation around individual poles.
DIN Rail Mountable
DIN Rail Mountable for easy mounting/ demounting inside DB.
Dual Connect Terminal
Dual connect terminal at incoming side - Two types of busbars can be used, that is, Fork Type and Pin Type.
Terminal
The terminals are suitable for cables up to 25 mm 2 cross section area thus making it suitable for copper and aluminum cables.
Knob Locking
OFF position for personal safety during maintenance, ON position for extremely critical load
Trip Free Mechanism
Trip free mechanism – MCB trips even if held in ON position.
Life Saver, Energy Saver
Low efficient watt loss, thus energy.
As published by Havells. Verify critical parameters against the datasheet before specifying.
Havells Havells X7 MCB TP · 20 A · DHMYCTPM020 · DHMYCTPM020
Device typeMiniature circuit breaker (MCB)
SeriesX7
Poles3P (TP)
Rated current20 A
Trip curveC curve
Breaking capacity7.5 kA
Rated voltage240 V
Frequency50 Hz
Reference standardIS/IEC 60898-1
Country of originIndia
Current rating20 A
BrandHavells
Brand SKUDHMYCTPM020
ELINEC7PP99297
Sold asPer pc
TypeC Curve
Rating20 A
Execution poleTriple Pole (TP)
Ratings as published by Havells (Havells X7 price list, Apr 2026; havells.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

What current is this MCB rated for and what wire should I use with it?

This MCB is rated 20 A. As a rough guide for copper wiring in Indian homes, 6-10A usually goes with 1.5 sq mm lighting circuits, 16A with 2.5 sq mm socket circuits and 20-32A with 4-6 sq mm, but cable length and installation method matter, so have a licensed electrician confirm.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.