🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Havells TPN C MCB · 32 A · DHMXCTNZ032DHMXCTNZ032↓ 41% off1 / 3
BrandHavells
CategorySwitchgear
SpecificationMCB · 3P+N · 32 A · C curve · 6 kA · 240/415 V
Brand SKUDHMXCTNZ032
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Havells· In stock
Visit the Havells store

Havells TPN C MCB · 32 A · DHMXCTNZ032

Rating: 32 A
$14.60/pc-41%
$24.93
Wholesale · 15+ units
$13.88 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$14.60 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCB
TPN
32 A
C
6 kA
$14.60 /pc
Viewing above ↑
MCB
TPN
32 A
C
-
$21.24 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $13.88/pc on this product, applied automatically

Havells TPN C MCB is a switchgear product from Havells. Key ratings: rated voltage 240/415 V, rated current 32 A, poles 3P+N, trip curve C curve.

  • IS/IEC 60898-1
  • Flame-Retardant Thermoplastic Material
  • Superior Air Circulation
  • Hammer Trip mechanism
  • Suitable for protection against overload & short circuit for Motor and other Inductive loads
  • Line & Load Interchangeability
  • Ease of Installation
As published by Havells. Verify critical parameters against the datasheet before specifying.
Havells Havells TPN C MCB · 32 A · DHMXCTNZ032 · DHMXCTNZ032
Device typeMiniature circuit breaker (MCB)
SeriesREO
Poles3P+N (TPN)
Rated current32 A
Trip curveC curve
Breaking capacity6 kA
Rated voltage240/415 V
Frequency50 Hz
Reference standardIS/IEC 60898-1
Dimensions84 mm x 60.2 mm x 17.7 mm
Country of originIndia
Current rating32 A
BrandHavells
Brand SKUDHMXCTNZ032
ELINE3KFKKDP3J
Sold asPer pc
TypeTripple Pole with Neutral
CurveC Curve
Humidity95 % RH
No. of Poles1P, 1P+N, 2P, 3P+N, 4P
Type Or Series6 A - 63 A, C- Curve
Rated Frequency50 Hz
Protection ClassIP20
Shock Resistance40 mm free fall
Mounting Din Rail35 mm x 7.5 mm
Energy Limit Class3
Rated Voltage (Ue)240 V AC / 415 V AC
Installation PositionVertical / Horizontal
Operating Temperature-5 °C to 50 °C
Rated Impulse Voltage4 kV
Magnetic Release Setting( 5 - 10 ) In - C Curve
Rated Insulation Voltage690 V
Tightening Torque Capacity2 Nm
Terminal Capacity (Maximum)25 mm²
Rated Short Circuit Breaking Capacity6 kA
Electrical / Mechanical Endurance (No. of operations) Minimum10000 ≤ 32 A (No. of operations), 20000 > 32 A (No. of operations)
Ratings as published by Havells (Havells REO switchgear price list, Feb 2023; havells.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

What current is this MCB rated for and what wire should I use with it?

This MCB is rated 32 A. As a rough guide for copper wiring in Indian homes, 6-10A usually goes with 1.5 sq mm lighting circuits, 16A with 2.5 sq mm socket circuits and 20-32A with 4-6 sq mm, but cable length and installation method matter, so have a licensed electrician confirm.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.

No reviews yet