Havells Phase Selector Horizontal · 4 Quadrant DB · 4 way · 40 A · DHDSCHDRZ04040DHDSCHDRZ04040↓ 41% off1 / 2
BrandHavells
CategoryDB & Panels
SpecificationPhase selector · 4 way · Three phase (TPN) · 40 A
Brand SKUDHDSCHDRZ04040
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Havells· In stock
Visit the Havells store

Havells Phase Selector Horizontal · 4 Quadrant DB · 4 way · 40 A · DHDSCHDRZ04040

$86.94/pc-41%
$146.34
Wholesale · 15+ units
$82.61 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$86.94 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $82.61/pc on this product, applied automatically

4 Way, 40 A (DD)

  • Application : Suitable for flush mounting and surface mounting
  • Range : 4 W, 6 W & 8 W
  • Specification : IEC 61439-3, IS:13032 & IS:8623
  • Disclaimer: Product images are for illustrative purposes and may differ from the actual product
With inbuilt 3 nos. of 40 A/63 A phase selector switches and 3 nos. piano switches
To indicate the phases available or in use
Suitable for Flush mounting and Surface mounting
Options available in market for mounting
With 100 A copper busbar for each phase
Max Rating of copper bus bar
With neutral bar, earth bar and cable ties for cable management
Easy and clean connections is made
Fully insulated busbar and neutral bar
Prevent accidentaly touching of bus bar
Provision for 8 W incomer, indicator light R, Y, B (FP MCB/ Isolator/RCCB)
Additional provision for 8 W incomer with indicating light
Supplied with wire set
Ease for connection, simply installing the breakers to the pre installed wires provided
IP 42
Protected against solid objects over 1.0 mm e.g. wires. Protected against falling drops of water, if the case is disposed up to 15 from vertical
As published by Havells. Verify critical parameters against the datasheet before specifying.
Havells Havells Phase Selector Horizontal · 4 Quadrant DB · 4 way · 40 A · DHDSCHDRZ04040 · DHDSCHDRZ04040
Device typePhase selector
Ways4 way
PhaseThree phase (TPN)
Rated current40 A
Poles3P+N (TPN)
MountingHorizontal
Country of originIndia
Enclosure typeDistribution board - TPN (three phase)
Reference standardIS 8623 / IEC 61439
BrandHavells
Brand SKUDHDSCHDRZ04040
ELINE7K6DD9243
Sold asPer pc
TypeManual
Rating40 A
Execution poleThree Pole & Neutral (TPN)
Number of Ways4 way
Ratings as published by Havells (Product name; havells.com; Havells Consumer Switchgear price list, Apr 2026). Verify critical parameters against the datasheet before specifying.
Read: How Many Ways Should Your Distribution Board Have? 4, 8, 12 or 16 Way Explained →
What does 8 way or 12 way mean in a distribution board?
The number of single-module slots on the outgoing rail. Each single-pole MCB uses one way; wider devices like a double-pole RCCB use two or more. The usable circuit count is therefore the way count minus the width of incomer and protection devices.
How many ways do I need for a 2BHK?
Usually 8 to 12: two lighting circuits, two socket circuits, kitchen power, plus dedicated ways per AC and geyser, the RCCB's two ways, and spares. Buy 12 if the kitchen is appliance-heavy or an AC may be added later.
What is the difference between SPN and TPN distribution boards?
SPN boards serve single-phase (230 V) supplies with one phase busbar. TPN boards serve three-phase (415 V) supplies with three phase sections plus neutral, letting circuits balance across phases. Your electricity connection type decides which you need.
What does SPN mean in a distribution board?

SPN stands for Single Pole and Neutral, a DB for single-phase supply with a phase busbar, a neutral link and an earth bar. It is the standard DB for most Indian homes and small shops with single-phase connections.

How many ways do I need for a 2BHK or 3BHK flat?

Count one way per circuit (lighting, sockets, each AC, geyser, kitchen, etc.) plus incomer space, then add about 20-30% spare for future loads. A typical 2BHK uses around 8-12 ways and a 3BHK around 12-16 ways, but your circuit plan decides it.

Can I install an RCCB in this DB?

Most SPN DBs have incomer space for a DP MCB or isolator plus a 2-module RCCB, but this depends on the board. Check the incomer configuration, or choose an RCCB-ready DB if you want shock protection for all circuits.

Is flush mounting or surface mounting better?

Flush (concealed) DBs are recessed into the wall and suit new construction or renovation, while surface-mounted DBs are fixed on the wall and easier to retrofit. Measure the wall depth before choosing a flush DB.

Does the DB come with MCBs?

Most distribution boards are sold empty with busbar, neutral link and earth bar, and MCBs are bought separately. Check the package contents on the product page.

No reviews yet