Havells RCBO ‘A' Type SPN & 2M · 32 A · 30 mA · DHBMACDP4030032DHBMACDP4030032↓ 51% off
BrandHavells
CategorySwitchgear
SpecificationRCBO · 2P (DP) · 32 A · 30 mA
Brand SKUDHBMACDP4030032
AvailabilityOut of stock
Delivery8 to 15 business days after dispatch
Havells· Out of stock
Visit the Havells store

Havells RCBO ‘A' Type SPN & 2M · 32 A · 30 mA · DHBMACDP4030032

⚡ Ranked #4 in Top 10 MCBs & RCCBs for Indian Homes · Dedicated AC, geyser or EV circuits →
$45.68/pc-51%
$92.30
Out of stock
This one cannot be ordered right now. These match its specification and are in stock:
Same specificationRCBO · Type A · 2P / 1P+N (single phase) · 32 A · 30 mA
LegrandIn stock
DX3 RCBO · 2P (DP) · 32 A · 30 mA · 411326
$69.98/pc-31%
$101.24
Compare all 7 in-stock alternatives ↓
Need this exact model? Email info@elumenuvo.com and we will source it for you.
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCBO · Type A
2P / 1P+N (single phase)
32 A
-
30 mA
$45.68 /pc
Viewing above ↑
RCBO
2P / 1P+N (single phase)
32 A
-
30 mA
$69.98 /pc
RCBO · Type A
2P / 1P+N (single phase)
32 A
C
30 mA
$89.80 /pc
RCBO · Type A
2P / 1P+N (single phase)
32 A
C
30 mA
$95.77 /pc
RCBO · Type A
2P / 1P+N (single phase)
32 A
C
30 mA
$109.58 /pc
RCBO
2P / 1P+N (single phase)
32 A
C
30 mA
$110.50 /pc
RCBO
2P / 1P+N (single phase)
32 A
-
30 mA
$172.68 /pc
RCBO
2P / 1P+N (single phase)
32 A
C
30 mA
$228.79 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $43.41/pc on this product, applied automatically

30 mA - 32 A

  • Application : Protection against over currents and earth leakage faults
  • Rating : 16 A to 63 A
  • Specification : IS 12640 : Part 2/ IEC 61009-1 / EN : 61009-1
Test Button
Test button for regular inspection/testing.
Inscription Window
Inscription window with ON & OFF indication.
Proper Cable Termination
Proper cable termination with 25 mm 2 slot and safety shutter.
As published by Havells. Verify critical parameters against the datasheet before specifying.
Havells Havells RCBO ‘A' Type SPN & 2M · 32 A · 30 mA · DHBMACDP4030032 · DHBMACDP4030032
Device typeResidual current breaker with overload protection (RCBO)
SeriesSTADx
Poles2P (DP)
Rated current32 A
Sensitivity (IΔn)30 mA
Country of originIndia
Current rating32 A
Reference standardIS/IEC 60898-1
BrandHavells
Brand SKUDHBMACDP4030032
ELINE7RMDJFG4J
Sold asPer pc
Ratings as published by Havells (Havells STADx price list, Mar 2026; havells.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
What is the difference between RCBO and RCCB?

An RCBO combines an MCB and an RCCB in one device, protecting a single circuit against overload, short circuit and earth leakage. An RCCB only handles earth leakage and needs separate MCBs (RCBOs are covered by IS 12640 (Part 2)).

Why use RCBOs instead of one main RCCB?

With RCBOs, a leakage fault on one circuit trips only that circuit, so the rest of the house keeps power and it is easier to find the fault. They cost more and take more DB space than one RCCB with several MCBs, so many homes use RCBOs only on critical circuits like geyser, washing machine and outdoor points.

Can I use an RCBO for my geyser or water pump?

Yes, an RCBO suits geysers, pumps and other loads in wet areas because it gives shock protection and overload protection on that one circuit. Choose the current rating and curve as you would for an MCB, based on the appliance's rated current and the cable, and have a licensed electrician confirm.

Does an RCBO need a neutral connection?

Yes. The RCBO compares phase and neutral current to detect leakage, so the circuit's neutral must pass through it and must not be shared with any other circuit.

Will an RCBO fit in a normal MCB distribution board?

RCBOs mount on the standard 35mm DIN rail, but many are 2 modules wide or need a separate neutral connection, so check that your DB has enough free ways and space. Some compact single-module RCBOs fit like an SP MCB; refer to the product's module width.

No reviews yet