🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB K6-31Z-01 Mini Contactor Relay 24V 40-450Hz · GJH1211001R0311GJH1211001R0311↓ 53% off
BrandABB
CategorySwitchgear
SpecificationK6-31Z-01 · Mini Contactors
Brand SKUGJH1211001R0311
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB K6-31Z-01 Mini Contactor Relay 24V 40-450Hz · GJH1211001R0311

$20.79/pc-53%
$44.06
Wholesale · 15+ units
$19.74 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$20.79 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $19.74/pc on this product, applied automatically

The K6-31Z mini contactor relay is a compact 4 pole contactor relay with screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors relays are used in residential buldings, commercial buildings and industrial applications for switching of control signals up to 3 A / 400 V (AC-15). Further features are the silent coil, a switch position indication and the integrated possibility for rail or wall mounting.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB K6-31Z-01 Mini Contactor Relay 24V 40-450Hz · GJH1211001R0311 · GJH1211001R0311
Device typeContactor
SeriesMini Contactors
Poles4P (FP)
FrequencyAuxiliary Circuit 50 Hz/Auxiliary Circuit 60 Hz/Auxiliary Circuit DC, Control Circuit 400 Hz/Control Circuit 50 Hz/Control Circuit 60 Hz, Main Circuit 60 Hz/Main Circuit 50 Hz/Main Circuit DC
Insulation voltage (Ui)690 V, acc. to UL/CSA 600 V
Country of originGermany
Reference standardIS/IEC 60898-1
BrandABB
Brand SKUGJH1211001R0311
ELINE64PH2K39K
Sold asPer pc
Mounting TypeDIN-rail, Screw
Package Width115 mm
Terminal TypeScrew Terminals
Package Height54 mm
Package Length280 mm
Number of Poles4
Coil ConsumptionAverage Holding Value 50 Hz 3.5 V - A, Average Pull-in Value 50 Hz 3.5 V - A
Rated Frequency (f)Auxiliary Circuit 50 Hz/Auxiliary Circuit 60 Hz/Auxiliary Circuit DC, Control Circuit 400 Hz/Control Circuit 50 Hz/Control Circuit 60 Hz, Main Circuit 60 Hz/Main Circuit 50 Hz/Main Circuit DC
Package Gross Weight1.82 kg
Extended Product TypeK6-31Z-01
Ambient Air TemperatureOperation -25 ... +55 °C, Storage -40 ... +80 °C
General Use Rating UL/CSA(600 V AC) 5 A
Number of Aux Contacts NC1
Number of Main Contacts NC0
Number of Main Contacts NO0
Max Operating Voltage UL/CSAAuxiliary Circuit 600 V AC / DC
Rated Insulation Voltage (Ui)690 V, acc. to UL/CSA 600 V
Max Electrical Switching FrequencyAC-15 600 cycles per hour, DC-13 600 cycles per hour
Rated Control Circuit Voltage (Uc)24V AC
Rated Operational Current AC-15 (Ie)(120 V) 4 A, (220 / 240 V) 4 A, (240 V) 4 A, (24 V) 4 A, (380 / 400 V) 3 A, (500 V) 2 A
Rated Operational Current DC-13 (Ie)(110 V) 0.7 A, (220 / 240 V) 0.4 A, (24 V) 2.5 A
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit 6 A
Automation & Control Rated Operational VoltageAuxiliary Circuit 12 ... 240 V DC/Auxiliary Circuit 12 ... 500 V AC / DC/Auxiliary Circuit 690 V
Product RangeMini Contactors
Ratings as published by ABB (shop.in.abb.com listing for GJH1211001R0311, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.