ABB S804PV-SP10 · 2CCF019622R00012CCF019622R0001↓ 2% off
BrandABB
CategorySwitchgear
Specification4P (FP) · 10 A · 5 kA · acc. to IEC 60947-2 1500 V DC · SP
Brand SKU2CCF019622R0001
AvailabilityOut of stock
Delivery8 to 15 business days after dispatch
ABB· Out of stock
Visit the ABB store

ABB S804PV-SP10 · 2CCF019622R0001

$438.42/pc-2%
$447.38
Out of stock

We list this so you can see the spec and our price, but it cannot be ordered right now. Email info@elumenuvo.com and we will source it for you.

🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $416.51/pc on this product, applied automatically

The S804PV-SP10 is a P4-pole High Performance Circuit breaker for photovoltaics (DC) with B-characteristic, with cage terminal and a rated current of 10 A. It is a current limiting device with a maximum breaking capacity of 5kA at 1500V. It can be used for voltages up to 1500V DC. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechan

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB S804PV-SP10 · 2CCF019622R0001 · 2CCF019622R0001
SeriesS800PV
Poles4P (FP)
Rated current10 A
Breaking capacity5 kA
Rated voltageacc. to IEC 60947-2 1500 V DC
Frequency0 Hz
Ultimate breaking capacity (Icu)5 kA
Service breaking capacity (Ics)5 kA
ReleaseSP
Insulation voltage (Ui)acc. to IEC/EN 60664-1 1500 V
Impulse withstand (Uimp)8 kV
Terminal capacityFlexible 0 … 50 mm²
Ingress protectionIP20
Reference standardIEC/EN 60947-2
Net weight0.98 kg
Device typeMiniature circuit breaker (MCB)
Current rating10 A
BrandABB
Brand SKU2CCF019622R0001
ELINERJD44FRM6
Sold asPer pc
Ratings as published by ABB (abb.com product data, datasheet 9AKK108468A9560; Product name). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.