🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB PSR37-600-11 · Softstarter · 37 A · 208... · 600 V AC · 1SFA896110R11001SFA896110R1100↓ 53% off
BrandABB
CategorySwitchgear
Specification37 A · 600 V AC
Brand SKU1SFA896110R1100
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB PSR37-600-11 · Softstarter · 37 A · 208... · 600 V AC · 1SFA896110R1100

$796.16/pc-53%
$1,686.77
Wholesale · 15+ units
$756.36 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$796.16 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $756.36/pc on this product, applied automatically

The softstarter PSR37-600-11 has a rated maximum operational current of 37 A with an operating voltage span from 208...600 V AC. The rated control voltage is 24 V AC/DC. PSR features a two-phase control soft start and stop through a voltage ramp. It has built-in bypass for easy installation and energy saving. A RUN and a TOR signal is available from a relay output in NO (normally open state). The

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB PSR37-600-11 · Softstarter · 37 A · 208... · 600 V AC · 1SFA896110R1100 · 1SFA896110R1100
SeriesPSR37
Rated current37 A
Rated voltage600 V AC
Frequency50/60 Hz
Terminal capacityRigid 1x 6 ... 35 mm²
Ingress protectionIP10
Net weight1 kg
Country of originSweden
Device typeMiniature circuit breaker (MCB)
Current rating37 A
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SFA896110R1100
ELINE4HJ2KJR4G
Sold asPer pc
Ratings as published by ABB (abb.com product data, datasheet 1SFC132012C0201; shop.in.abb.com listing for 1SFA896110R1100, 23 Sep 2026; Product name). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
No reviews yet