🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB UPS PowerValue 11RT G2 10 kVA IN · 4NWP100151R00044NWP100151R0004
BrandABB
CategorySwitchgear
SpecificationUPS PowerValue 11RT G2 10 kVA IN · UPS
Brand SKU4NWP100151R0004
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB UPS PowerValue 11RT G2 10 kVA IN · 4NWP100151R0004

$1,779.25/pc
Wholesale · 15+ units
$1,690.29 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$1,779.25 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $1,690.29/pc on this product, applied automatically

UPS PowerValue 11RT G2 10 kVA S India , including OVCD, with external battery provision

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB UPS PowerValue 11RT G2 10 kVA IN · 4NWP100151R0004 · 4NWP100151R0004
SeriesUPS
Country of originChina
Device typeMiniature circuit breaker (MCB)
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU4NWP100151R0004
ELINEG9M6JJPDD
Sold asPer pc
ColorBlack
UPS Rating6kVA - 10kVA
Mounting TypeRack Tower Convertible
Package Width438 mm
Package Height86.5 mm
Package Length603 mm
UPS Battery TypeExternal battery Model
Package Gross Weight15.5 Kg
Extended Product TypeUPS PowerValue 11RT G2 10 kVA IN
UPS Type ElectrificationRack Tower Model
Declaration of Conformity - CEBIS
Product RangeUPS
Ratings as published by ABB (shop.in.abb.com listing for 4NWP100151R0004, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
No reviews yet