ABB AL12-30-01 220V DC Contactor · 1SBL163001R88011SBL163001R8801↓ 53% off
BrandABB
CategorySwitchgear
SpecificationAL12-30-01 220V DC · AL Contactors
Brand SKU1SBL163001R8801
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB AL12-30-01 220V DC Contactor · 1SBL163001R8801

$37.41/pc-53%
$79.26
Wholesale · 15+ units
$35.54 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$37.41 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $35.54/pc on this product, applied automatically

AL12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The AL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. AL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB AL12-30-01 220V DC Contactor · 1SBL163001R8801 · 1SBL163001R8801
Device typeContactor
SeriesAL Contactors
Poles3P (TP)
FrequencyAuxiliary Circuit 50 / 60 Hz
Insulation voltage (Ui)acc. to IEC 60947-4-1 1000 V
Country of originIndia
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SBL163001R8801
ELINE4MC7PDRF9
Sold asPer pc
Operate TimeBetween Coil De-energization and NO Contact Opening 10 ... 17 millisecond
Package Width86 mm
Product ClassBlock Contactors
Terminal TypeScrew Terminals
Package Height51 mm
Package Length141 mm
Number of Poles3
Coil ConsumptionAverage Holding Value, from Warm State 3 W
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Package Gross Weight0.52 kg
Extended Product TypeAL12-30-01 220V DC
Rated Frequency Limits25 ... 400 Hz
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 3 hp
General Use Rating UL/CSA(600 V AC) 25 A
Number of Aux Contacts NC1
Number of Aux Contacts NO0
Number of Main Contacts NC0
Number of Main Contacts NO3
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 1000 V
Rated Operational Power AC-3 (Pe)(415 V) 5.5 kW
Max Electrical Switching Frequency(AC-1) 600 cycles per hour
Max Mechanical Switching Frequency3600 cycles per hour
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 27 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 12 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A
Rated Operational Current DC-13 (Ie)(24 V) 6 / 144 A
Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 A
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 28 A
Product RangeAL Contactors
Ratings as published by ABB (shop.in.abb.com listing for 1SBL163001R8801, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.

No reviews yet