🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB 220-240 V AC Relay · CM-MSE Thermistor motor protection relay 1n/o · 1SVR550801R93001SVR550801R9300↓ 53% off
BrandABB
CategorySwitchgear
SpecificationRelay · 4 A · 240 V AC
Brand SKU1SVR550801R9300
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB 220-240 V AC Relay · CM-MSE Thermistor motor protection relay 1n/o · 1SVR550801R9300

$85.84/pc-53%
$181.85
Wholesale · 15+ units
$81.54 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$85.84 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $81.54/pc on this product, applied automatically

The CM-MSE relay is from the CM thermistor motor protection relay range. This relay operates with a rated control supply voltage of 220-240 V AC and has a 1 n/o output contact rated at 250 V / 4 A. It features one sensor circuit for monitoring of PTC temperature sensors or bimetals. This relay offers automatic reset and works according to the closed-circuit principle. A sealable transparent cover

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB 220-240 V AC Relay · CM-MSE Thermistor motor protection relay 1n/o · 1SVR550801R9300 · 1SVR550801R9300
Device typeRelay
Rated current4 A
Rated voltage240 V AC
FrequencySupply Circuit 50/60 Hz
Insulation voltage (Ui)Measuring Circuit / Output Circuit 250 V
Impulse withstand (Uimp)Output Circuit 4 kV
Width1.5 modules (22.5 mm)
Terminal capacityFlexible with Ferrule 2x 1.5 mm²
Ingress protectionIP50
Reference standardCAN/CSA C22.2 No.14, IEC/EN 63000, IEC/EN 61000-6-2, IEC/EN 61000-6-3, UL 508
Net weight0.104 kg
Country of originBulgaria
Current rating4 A
BrandABB
Brand SKU1SVR550801R9300
ELINE34R4RR29R
Sold asPer pc
Ratings as published by ABB (abb.com product data, datasheet 2CDC110004C0210_02; shop.in.abb.com listing for 1SVR550801R9300, 23 Sep 2026; Product name). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
What is the difference between MPCB and MCB for a motor?

An MPCB has an adjustable overload setting matched to the motor's current and a magnetic trip set to handle motor starting current, plus phase loss sensitivity. An MCB has fixed overload settings meant for cables, so it does not protect a motor as precisely (MPCBs are covered by IS/IEC 60947-2 and 60947-4-1).

Can an MPCB replace an overload relay and fuses?

Yes, an MPCB gives short-circuit and overload protection plus isolation in one device, so with a contactor it forms a compact DOL starter without a separate overload relay or fuses. Check the manufacturer's coordination table for the right contactor pairing.

Can I start and stop the motor directly with the MPCB?

Yes, an MPCB can be used as a manual motor starter for occasional on/off switching. For frequent starts, remote control or float/pressure switch operation, pair it with a contactor.

Which accessories are available for an MPCB?

Common accessories include auxiliary contacts, trip-indication contacts, undervoltage and shunt releases, enclosures for wall mounting and connection links to contactors. These are usually specific to the MPCB range.

My MPCB trips when the motor starts - what should I check?

Check that the dial is set to the motor's full-load current, that all three phases are present and balanced, and that the pump or load is not jammed. If the motor current is near the top of the range, the next range up may be needed; consult an electrician before increasing settings.

No reviews yet