ABB ZL400 Main Contact Kit · 1SFN165703R10001SFN165703R1000↓ 5% off
BrandABB
CategorySwitchgear
Specification3 pole main contact set for a contactor consisting of fixed contacts, moving contacts, springs and hardware
Brand SKU1SFN165703R1000
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB ZL400 Main Contact Kit · 1SFN165703R1000

$629.00/pc-5%
$660.44
Wholesale · 15+ units
$597.56 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$629.00 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $597.56/pc on this product, applied automatically

ABB ZL400 Main Contact Kit (ABB article 1SFN165703R1000) belongs to ABB's AF Contactors range, listed under Spares. 3 pole main contact set for a contactor consisting of fixed contacts, moving contacts, springs and hardware. Sold by Elume with a GST invoice and delivery across India.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB ZL400 Main Contact Kit · 1SFN165703R1000 · 1SFN165703R1000
Net weight1.32 kg
Country of originFrance
Device typeMiniature circuit breaker (MCB)
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SFN165703R1000
ELINEKMKG926RD
Sold asPer pc
Ratings as published by ABB (shop.in.abb.com listing for 1SFN165703R1000, 23 Sep 2026; abb.com product data, datasheet 1SBC100214C0202). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.