ABB XT2H 160 TMD 32-320 4p F F · 1SDA067618R11SDA067618R1↓ 53% off
BrandABB
CategorySwitchgear
SpecificationC.BREAKER TMAX XT2H 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 32-320 A
Brand SKU1SDA067618R1
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB XT2H 160 TMD 32-320 4p F F · 1SDA067618R1

Poles: 4
$355.42/pc-53%
$753.00
Wholesale · 15+ units
$337.65 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$355.42 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $337.65/pc on this product, applied automatically

ABB XT2H 160 TMD 32-320 4p F F is an MCCB from ABB. It protects feeders and sub-mains against overload and short circuit and is the incomer or outgoing breaker of a panel. Key ratings: Poles 4P (FP), Rated current 32 A, Icu 70 kA, Release TMD, Setting range 22.4...32 A, Rated voltage 690 V AC. It is built to IEC60947-2.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB XT2H 160 TMD 32-320 4p F F · 1SDA067618R1 · 1SDA067618R1
Device typeMoulded case circuit breaker (MCCB)
SeriesSACE Tmax XT
Frame size160 A
Poles4P (FP)
Rated current32 A
Rated voltage690 V AC
Frequency50 / 60 Hz
Ultimate breaking capacity (Icu)70 kA
Service breaking capacity (Ics)70 kA
Setting range22.4...32 A
ReleaseTMD
Insulation voltage (Ui)1000 V
Impulse withstand (Uimp)8 kV
Terminal capacityBusbar 32.5..100 mm²
Reference standardIEC60947-2
Net weight1.45 kg
Country of originItaly
Current rating320 A
BrandABB
Brand SKU1SDA067618R1
ELINE2HMRPJC2G
Sold asPer pc
Ratings as published by ABB (abb.com product data, datasheet 1SDC210100D0206; Product name; shop.in.abb.com listing for 1SDA067618R1, 23 Sep 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.