ABB XT2H 160 TMD 5-50 4p F F · 1SDA067610R11SDA067610R1↓ 53% off
BrandABB
CategorySwitchgear
SpecificationXT2H 160 TMD 5-50 4p F F · TMax XT
Brand SKU1SDA067610R1
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB XT2H 160 TMD 5-50 4p F F · 1SDA067610R1

$387.43/pc-53%
$820.83
Wholesale · 15+ units
$368.06 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$387.43 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $368.06/pc on this product, applied automatically

C.BREAKER TMAX XT2H 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 5-50 A

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB XT2H 160 TMD 5-50 4p F F · 1SDA067610R1 · 1SDA067610R1
Device typeMoulded case circuit breaker (MCCB)
SeriesTMax XT
Poles4P (FP)
Rated current5 A
Rated voltage690 V AC ; 500 V DC
Service breaking capacity (Ics)70 kA
Setting range3,5...5 A
ReleaseTM
Insulation voltage (Ui)1000 V
Impulse withstand (Uimp)8 kV
Reference standardIEC
Country of originItaly
BrandABB
Brand SKU1SDA067610R1
ELINE42HHFH2FD
Sold asPer pc
SizeXT2H
Sub-typeXT2
StandardsIEC
Release TypeTM
Package Width130 mm
Product ClassMoulded Case Circuit Breakers
Package Height208 mm
Package Length145 mm
Number of Poles4
Rated Voltage (Ur)690 V
Package Gross Weight1.55 kg
Selectivity CategoryA
Electrical Durability120 cycles per hour, 8000 cycle
Extended Product TypeXT2H 160 TMD 5-50 4p F F
Rated Current El ED (In)5A
Rated Operational Voltage690 V AC ; 500 V DC
Rated Insulation Voltage (Ui)1000 V
Rated Uninterrupted Current (Iu)160 A
Short Circuit Performance Level70kA
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 100 kA, (230 V AC) 100 kA, (240 V AC) 100 kA, (380 V AC) 70 kA, (415 V AC) 70 kA, (440 V AC) 65 kA, (500 V AC) 50 kA, (525 V AC) 30 kA, (690 V AC) 15 kA, (250 V DC) 2 Poles
Product RangeTMax XT
Ratings as published by ABB (shop.in.abb.com listing for 1SDA067610R1, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.