ABB T6H 800 PR221DS-LS/I In=800 4p F F · 1SDA060294R11SDA060294R1
BrandABB
CategorySwitchgear
SpecificationT6H 800 PR221DS-LS/I In=800 4p F F · TMax T
Brand SKU1SDA060294R1
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB T6H 800 PR221DS-LS/I In=800 4p F F · 1SDA060294R1

$1,968.11/pc
Wholesale · 15+ units
$1,869.69 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$1,968.11 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $1,869.69/pc on this product, applied automatically

C.BREAKER TMAX T6H 800 FIXED FOUR-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC PR221DS-LS/I R 800

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB T6H 800 PR221DS-LS/I In=800 4p F F · 1SDA060294R1 · 1SDA060294R1
Device typeMoulded case circuit breaker (MCCB)
SeriesTMax T
Poles4P (FP)
Rated current800 A
Rated voltage690 V AC
Service breaking capacity (Ics)70 kA
ReleaseEL
Insulation voltage (Ui)1000 V
Impulse withstand (Uimp)8 kV
Reference standardIEC
Country of originItaly
BrandABB
Brand SKU1SDA060294R1
ELINE3R7DM9J7M
Sold asPer pc
SizeT6
Sub-typeT6
StandardsIEC
Release TypeEL
Package Width305 mm
Product ClassMoulded Case Circuit Breakers
Package Height285 mm
Package Length370 mm
Number of Poles4
Package Gross Weight14 kg
Electrical Durability5000 cycle, 60 cycles per hour
Extended Product TypeT6H 800 PR221DS-LS/I In=800 4p F F
Rated Current El ED (In)Main Circuit 800A
Rated Operational Voltage690 V AC
Rated Insulation Voltage (Ui)1000 V
Rated Uninterrupted Current (Iu)800 A
Short Circuit Performance Level70kA
Rated Impulse Withstand Voltage (Uimp)8 kV
Rated Short-time Withstand Current (Icw)for 1 s 10 kA
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 100 kA, (230 V AC) 100 kA, (380 V AC) 70 kA, (400 V AC) 70 kA, (415 V AC) 70 kA, (440 V AC) 50 kA, (500 V AC) 50 kA, (690 V AC) 19 kA
Product RangeTMax T
Ratings as published by ABB (shop.in.abb.com listing for 1SDA060294R1, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
No reviews yet