ABB ONE20M2G Enclosed Switch Disconnector · 1SCA135532R10011SCA135532R1001↓ 53% off
BrandABB
CategorySwitchgear
SpecificationONE20M2G · ONE20
Brand SKU1SCA135532R1001
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB ONE20M2G Enclosed Switch Disconnector · 1SCA135532R1001

$13.89/pc-53%
$29.42
Wholesale · 15+ units
$13.61 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$13.89 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $13.61/pc on this product, applied automatically

The plastic enclosed switch disconnector, is well suited for commersial and residential use. There are 3 color alternatives available, red/yellow, dark grey, and white. Typical applications could be fans, pumps, kitchen appliancies etc. The product withstand water and rain, acc. to class IP67, and is well suited for indoor and outdoor us. The plastic is UV protected. Two cable glands are included in the delivery. The terminals are easily available, thanks to the enclosure design and the removable switch. PE terminal included.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB ONE20M2G Enclosed Switch Disconnector · 1SCA135532R1001 · 1SCA135532R1001
Device typeIsolator (switch disconnector)
SeriesONE20
Poles2P (DP)
Insulation voltage (Ui)acc. to IEC/EN 60664-1 690 V
Impulse withstand (Uimp)4 kV
Reference standardIEC 60947-1, -3
Country of originFinland
BrandABB
Brand SKU1SCA135532R1001
ELINEK4K6G6C47
Sold asPer pc
StandardsIEC 60947-1, -3
Package Width85 mm
Package Height66 mm
Package Length103 mm
Number of Poles2
Package Gross Weight0.15 kg
Extended Product TypeONE20M2G
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 690 V
Rated Impulse Withstand Voltage (Uimp)4 kV
Product RangeONE20
Ratings as published by ABB (shop.in.abb.com listing for 1SCA135532R1001, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
What is the difference between an isolator and an MCB?

An isolator (switch-disconnector) only switches the circuit on and off and does not trip on overload or short circuit, while an MCB provides protection. Isolators are used as main switches in DBs or near equipment for safe maintenance, and must be backed by a suitable MCB, MCCB or fuse.

Can I use an isolator as the main switch in my DB?

Yes, a DP isolator for single-phase or 4P isolator for three-phase is commonly used as the DB incomer, provided protection is given upstream (by the meter-side fuse or MCB) and on each outgoing circuit. Its current rating should be equal to or higher than the upstream protection rating.

Is this isolator safe to switch on load?

Switch-disconnectors to IS/IEC 60947-3 are rated for switching under load according to their utilisation category, such as AC-22 for mixed resistive and inductive loads or AC-23 for motor loads. Check the category on the product before using it to switch motors directly.

2 pole or 4 pole isolator - which one do I need?

Use 2 pole for single-phase supply (phase and neutral) and 4 pole for three-phase supply with neutral, so all live conductors are disconnected during maintenance. A 3 pole isolator is used where no neutral is switched, such as some motor feeders.

Can an isolator be locked off for maintenance?

Many isolators and rotary switch-disconnectors have a padlocking provision in the OFF position so no one can switch them on while work is in progress. Check for the lock-off feature if it is needed for your site's safety procedures.

No reviews yet