ABB CA4-01 Auxiliary Contact Block · 1SBN010110R10011SBN010110R1001↓ 53% off
BrandABB
CategorySwitchgear
SpecificationCA4-01 · AF Contactors
Brand SKU1SBN010110R1001
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB CA4-01 Auxiliary Contact Block · 1SBN010110R1001

$3.45/pc-53%
$7.31
Wholesale · 15+ units
$3.39 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$3.45 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $3.39/pc on this product, applied automatically

The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits for standard industrial environments. Types of auxiliary contact blocks for front mounting: • CA4 1 or 4-pole block, with instantaneous N.O., N.C. contacts • CC4 1-pole block, with N.O. leading contact or N.C. lagging contact • CAT4 2-pole block, with instantaneous N.O. + N.C. contacts and A1 / A2 coil terminal connection on front face. Select the 4-pole auxiliary contact blocks CA4-..E, CA4-..M, CA4-..U or CA4-..N type, according to the contactor or contactor relay type for compliance with the standard requirements (see "Terminal marking and positioning"). Types of auxiliary contact blocks for side mounting: • CAL4 2-pole block, with instantaneous N.O. + N.C. contacts. For clipping onto the right- and/or left-hand side of the contactors. The auxiliary contact blocks are equipped with screw type connecting terminals delivered open, protected against accidental direct contact and bear the corresponding function marking.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB CA4-01 Auxiliary Contact Block · 1SBN010110R1001 · 1SBN010110R1001
SeriesAF Contactors
FrequencyAuxiliary Circuit 50 / 60 Hz
Insulation voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
Country of originCzech Republic
Device typeMiniature circuit breaker (MCB)
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SBN010110R1001
ELINE2P3R3J6H2
Sold asPer pc
Mounting TypeFront mounting
Package Width100 mm
Product ClassBlock Contactors Accessories
Terminal TypeScrew Terminals
Package Height10 mm
Package Length100 mm
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Mounted Aux Contacts0 NO, 1 NC
Package Gross Weight0.014 kg
Extended Product TypeCA4-01
Number of Aux Contacts NC0
Number of Aux Contacts NO0
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
Max Electrical Switching FrequencyAC-15 1200 cycles per hour, DC-13 900 cycles per hour
Max Mechanical Switching Frequency3600 cycles per hour
Rated Operational Current AC-15 (Ie)(220 / 240 V) 4 A, (24 / 127 V) 6 A, (500 V) 2 A, (690 V) 2 A, (400 / 440 V) 3 A
Rated Operational Current DC-13 (Ie)(125 V) 0.55 A / 69 W, (24 V) 6 A / 144 W, (250 V) 0.27 A / 68 W, (48 V) 2.8 A / 134 W, (72 V) 1 A / 72 W, (110 V) 0.55 A / 60 W, (220 V) 0.27 A / 60 W, (400 V) 0.15 A / 60 W, (500 V) 0.13 A / 65 W, (600 V) 0.1 A / 60 W
Rated Short-time Withstand Current (Icw)for 0.1 s 140 A, for 1 s 100 A
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-5-1, q = 40 °C 16 A
Automation & Control Rated Operational VoltageAuxiliary Circuit 24 ... 690 V
Product RangeAF Contactors
Ratings as published by ABB (shop.in.abb.com listing for 1SBN010110R1001, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.