ABB AX80-30-11-81 24V 50/60Hz Contactor · 1SBL411074R81111SBL411074R8111↓ 53% off
BrandABB
CategorySwitchgear
SpecificationAX80-30-11-81 · AX Contactors
Brand SKU1SBL411074R8111
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB AX80-30-11-81 24V 50/60Hz Contactor · 1SBL411074R8111

$219.51/pc-53%
$465.07
Wholesale · 15+ units
$208.54 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$219.51 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $208.54/pc on this product, applied automatically

AX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB AX80-30-11-81 24V 50/60Hz Contactor · 1SBL411074R8111 · 1SBL411074R8111
Device typeContactor
SeriesAX Contactors
FrequencyAuxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz
Insulation voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Country of originBulgaria
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SBL411074R8111
ELINE2JKFJ9JR2
Sold asPer pc
Operate TimeBetween Coil De-energization and NC Contact Closing 7 ... 14 millisecond, Between Coil De-energization and NO Contact Opening 4 ... 11 millisecond, Between Coil Energization and NC Contact Opening 7 ... 22 millisecond, Between Coil Energization and NO Con
Package Width102 mm
Terminal TypeScrew Terminals
Package Height152 mm
Package Length143 mm
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz
Package Gross Weight1.16 kg
Extended Product TypeAX80-30-11-81
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C, Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C, Close to Contactor without Thermal O/L Relay -40 ... +70 °C, Near Contactor for Operation in Free Air -40 .
Full Load Amps Motor Use(120 V AC) Single Phase 80 A, (240 V AC) Single Phase 68 A, (200 ... 208 V AC) Three Phase 78.2 A, (220 ... 240 V AC) Three Phase 80 A, (440 ... 480 V AC) Three Phase 77 A, (550 ... 600 V AC) Three Phase 77 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 7-1/2 horsepower, (240 V AC) Single Phase 15 horsepower, (200 ... 208 V AC) Three Phase 25 horsepower, (220 ... 240 V AC) Three Phase 30 horsepower, (440 ... 480 V AC) Three Phase 60 horsepower, (550 ... 600 V AC) Three Phase 75 ho
General Use Rating UL/CSA(600 V AC) 105 A
Number of Aux Contacts NC1
Number of Aux Contacts NO1
Number of Main Contacts NC0
Number of Main Contacts NO3
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 22 kW, (380 / 400 V) 37 kW, (415 V) 40 kW, (440 V) 40 kW, (500 V) 45 kW, (690 V) 40 kW
Max Electrical Switching FrequencyAC-1 600 cycles per hour, AC-3 600 cycles per hour
Max Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24V; 60 Hz 24V
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 125 A, (690 V) 70 °C 85 A, (220 / 240 V) 55 °C 105 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 55 °C 80 A, (380 / 400 V) 55 °C 80 A, (415 V) 55 °C 80 A, (440 V) 55 °C 70 A, (500 V) 55 °C 65 A, (690 V) 55 °C 46 A
Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A, at 40 °C Ambient Temp, in Free Air, fro
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 125 A
Automation & Control Rated Operational VoltageAuxiliary Circuit 690 V, Main Circuit 690 V
Product RangeAX Contactors
Ratings as published by ABB (shop.in.abb.com listing for 1SBL411074R8111, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.

No reviews yet