ABB AF40-40-00-14 250-500V50/60HZ-DC Contactor · 1SBL347201R14001SBL347201R1400↓ 53% off
BrandABB
CategorySwitchgear
SpecificationAF40-40-00-14 · AF Contactors
Brand SKU1SBL347201R1400
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB AF40-40-00-14 250-500V50/60HZ-DC Contactor · 1SBL347201R1400

$306.92/pc-53%
$650.26
Wholesale · 15+ units
$291.57 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$306.92 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $291.57/pc on this product, applied automatically

AF40 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...). AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 4-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 4 N.O. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB AF40-40-00-14 250-500V50/60HZ-DC Contactor · 1SBL347201R1400 · 1SBL347201R1400
Device typeContactor
SeriesAF Contactors
Frequency50 / 60 Hz
Insulation voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Country of originFrance
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SBL347201R1400
ELINER24GJKM32
Sold asPer pc
Package Width150 mm
Product ClassBlock Contactors
Terminal TypeScrew Terminals
Package Height103 mm
Package Length150 mm
Rated Frequency (f)Main Circuit 50 / 60 Hz
Mounted Aux Contacts0 NO, 0 NC
Package Gross Weight1.27 kg
Extended Product TypeAF40-40-00-14
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... +70 °C
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 30 A, (550 ... 600 V AC) Three Phase 40 A, (120 V AC) Single Phase 3 A, (200 ... 208 V AC) Three Phase 10 A, (220 ... 240 V AC) Three Phase 15 A, (240 V AC) Single Phase 7-1/2 A
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 15 hp, (440 ... 480 V AC) Three Phase 30 hp, (550 ... 600 V AC) Three Phase 40 hp, (120 V AC) Single Phase 3 hp, (200 ... 208 V AC) Three Phase 10 hp, (240 V AC) Single Phase 7-1/2 hp
General Use Rating UL/CSA(600 V AC) 60 A
Number of Aux Contacts NC0
Number of Aux Contacts NO0
Number of Main Contacts NC0
Number of Main Contacts NO4
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 11 KWT, (380 / 400 V) 18.5 KWT, (415 V) 22 KWT, (440 V) 22 KWT, (500 V) 22 KWT, (690 V) 22 KWT
Max Electrical Switching FrequencyAC-1 600 cycles per hour
Max Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 250-500V; 50 Hz / 60 Hz 250-500V; 60 Hz 250-500V; DC Operation 250-500V
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 70 A, (690 V) 60 °C 60 A, (690 V) 70 °C 50 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 60 °C 40 A, (380 / 400 V) 60 °C 40 A, (415 V) 60 °C 40 A, (440 V) 60 °C 40 A, (500 V) 60 °C 35 A, (690 V) 60 °C 25 A
Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A, at 40 °C Ambient Temp, in Free Air, fro
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 105 A
Automation & Control Rated Operational VoltageMain Circuit 690 V
Product RangeAF Contactors
Ratings as published by ABB (shop.in.abb.com listing for 1SBL347201R1400, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.

No reviews yet