ABB AX40-30-01-84 110V50Hz/110-120V60Hz Contactor · 1SBL321074R84011SBL321074R8401↓ 53% off
BrandABB
CategorySwitchgear
SpecificationContactor · 3P (TP) · Auxiliary Circuit 690 V
Brand SKU1SBL321074R8401
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB AX40-30-01-84 110V50Hz/110-120V60Hz Contactor · 1SBL321074R8401

$91.37/pc-53%
$193.58
Wholesale · 15+ units
$86.80 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$91.37 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $86.80/pc on this product, applied automatically

AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB AX40-30-01-84 110V50Hz/110-120V60Hz Contactor · 1SBL321074R8401 · 1SBL321074R8401
Device typeContactor
Poles3P (TP)
Rated voltageAuxiliary Circuit 690 V
FrequencyAuxiliary Circuit 50 / 60 Hz
Insulation voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Impulse withstand (Uimp)Auxiliary Circuit 6 kV
Width3 modules (54 mm)
Ingress protectionIP20
Net weight0.667 kg
Country of originBulgaria
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SBL321074R8401
ELINE6DG7347G6
Sold asPer pc
Ratings as published by ABB (abb.com product data, datasheet 1SBC100187L0203; shop.in.abb.com listing for 1SBL321074R8401, 23 Sep 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.