ABB TF42-29 Thermal Overload Relay · 1SAZ721201R10521SAZ721201R1052↓ 5% off
BrandABB
CategorySwitchgear
SpecificationThermal overload relay · 3P (TP) · Auxiliary Circuit 600 V AC/DC · 29 A · 24 ... 29 A
Brand SKU1SAZ721201R1052
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB TF42-29 Thermal Overload Relay · 1SAZ721201R1052

$115.48/pc-5%
$121.26
Wholesale · 15+ units
$109.70 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$115.48 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $109.70/pc on this product, applied automatically

The TF42-29 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP function and

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB TF42-29 Thermal Overload Relay · 1SAZ721201R1052 · 1SAZ721201R1052
Device typeThermal overload relay
Poles3P (TP)
Rated voltageAuxiliary Circuit 600 V AC/DC
FrequencyAuxiliary Circuit 50 Hz
Operational current (Ie)29 A
Setting range24 ... 29 A
Insulation voltage (Ui)690 V
Impulse withstand (Uimp)Auxiliary Circuit 6 kV
Width2.5 modules (45 mm)
Terminal capacityFlexible with Ferrule 1/2x 2.5 ... 10 mm²
Ingress protectionIP20
Reference standardIEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L
Net weight0.145 kg
Country of originGermany
Current rating29 A
BrandABB
Brand SKU1SAZ721201R1052
ELINEMH26J2J9H
Sold asPer pc
Ratings as published by ABB (abb.com product data, datasheet 2CDC106023D0201; shop.in.abb.com listing for 1SAZ721201R1052, 23 Sep 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
What should I set the overload relay to?

Set it to the motor's full-load current from the nameplate, not higher. In a star-delta starter where the relay is in the phase winding circuit, it is set to about 0.58 times the full-load current.

Will this overload relay fit my contactor?

Most overload relays are designed to mount directly on specific contactor sizes of the same brand and range. For other brands or sizes, a separate mounting kit or panel mounting is needed, so check the compatibility list.

Does it protect against single phasing?

Most modern thermal overload relays have differential (single phasing) sensitivity and trip faster when one phase is lost, which helps protect three-phase motors. For full phase failure and phase reversal protection, a phase monitoring relay is also recommended.

What is trip class 10 and class 20?

Trip class indicates the maximum time to trip from cold at 7.2 times the set current: class 10 trips within 10 seconds and class 20 within 20 seconds (IS/IEC 60947-4-1). Class 10 suits normal motors, while class 20 or 30 is used for heavy-starting loads like crushers and fans with large inertia.

What is the difference between manual and auto reset?

In manual reset, someone must press the reset button after a trip, while auto reset lets the relay reset itself once it cools. Manual reset is generally safer, since the motor will not restart unexpectedly.