🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB MS132-4.0T Circuit Breaker for Primary Transformer Protection · 1SAM340000R10081SAM340000R1008↓ 53% off
BrandABB
CategorySwitchgear
SpecificationManual motor starter (MPCB) · 3P (TP) · 4.0 A · 690 V AC · 100 kA · 2.5 ... 4.0 A
Brand SKU1SAM340000R1008
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB MS132-4.0T Circuit Breaker for Primary Transformer Protection · 1SAM340000R1008

$94.82/pc-53%
$200.90
Wholesale · 15+ units
$90.08 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$94.82 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $90.08/pc on this product, applied automatically

The circuit breaker for transformer protection MS132-4.0T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 4.0 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current gen

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB MS132-4.0T Circuit Breaker for Primary Transformer Protection · 1SAM340000R1008 · 1SAM340000R1008
Device typeManual motor starter (MPCB)
Poles3P (TP)
Rated current4 A
Rated voltage690 V AC
Frequency50 Hz
Ultimate breaking capacity (Icu)100 kA
Service breaking capacity (Ics)100 kA
Operational current (Ie)4 A
Setting range2.5 ... 4.0 A
Insulation voltage (Ui)690 V
Impulse withstand (Uimp)6 kV
Width2.5 modules (45 mm)
Terminal capacityFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Ingress protectionIP20
Reference standardIEC/EN 60947-1, IEC/EN 60947-2, IEC/EN 60947-4-1, IEC 60335-2-40 A2L
Net weight0.265 kg
Country of originGermany
Current rating0 A
Breaking capacity100 kA
BrandABB
Brand SKU1SAM340000R1008
ELINEK44MDC7MJ
Sold asPer pc
Ratings as published by ABB (abb.com product data, datasheet 2CDC131058D0201; shop.in.abb.com listing for 1SAM340000R1008, 23 Sep 2026; Product name). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.

No reviews yet