🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB SK1-20 Signal Contact · 1SAM201903R10021SAM201903R1002↓ 53% off
BrandABB
CategorySwitchgear
SpecificationSK1-20 Signaling Contact 2 NO
Brand SKU1SAM201903R1002
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
ABB· In stock
Visit the ABB store

ABB SK1-20 Signal Contact · 1SAM201903R1002

$20.66/pc-53%
$43.76
Wholesale · 15+ units
$19.62 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$20.66 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $19.62/pc on this product, applied automatically

Signaling contacts SK1 with screw terminals signal the tripping of the manual motor starter. For SK1 the indication on the device itself is done with a protruding orange button. The contact positions of SK1 need to be manually reset after a tripping event by pushing the orange button. SK1 signaling contacts signal tripping regardless if it was caused by short-circuit, overload or electrical release (AA1 or UA1). They are attached on the right side of the manual motor starter. Signaling contacts SK1 are available as normally open or normally closed contacts.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB SK1-20 Signal Contact · 1SAM201903R1002 · 1SAM201903R1002
Rated voltage690 V AC
Insulation voltage (Ui)690 V
Impulse withstand (Uimp)Auxiliary Circuit 6 kV
Ingress protectionIP20
Net weight0.035 kg
Country of originBulgaria
Device typeMiniature circuit breaker (MCB)
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SAM201903R1002
ELINEGR7G7GRPF
Sold asPer pc
Ratings as published by ABB (abb.com product data, datasheet 1SBC100214C0202; shop.in.abb.com listing for 1SAM201903R1002, 23 Sep 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.