Honeywell Impact MCB Changeover Switch · 2P (DP) · 63 A · IH32PMCO63

Rating: 63 A
Poles: 2P (DP)
$27.01/pc-20%
$33.77
Wholesale · 15+ units
$25.67 /pc
Add to cart
Buy now
On order: delivered in 2 to 3 weeks. We order it from Honeywell for you once you place the order.
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$27.01 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
CHANGEOVER
DP
63 A
n/a
-
$27.01 /pc
Viewing above ↑
CHANGEOVER
DP
63 A
n/a
-
$21.47 /pc
CHANGEOVER
DP
63 A
n/a
-
$30.57 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $25.67/pc on this product, applied automatically

Honeywell Impact MCB Changeover Switch, 2P (DP), 63 A. Honeywell item code IH32PMCO63.

As published by Honeywell. Verify critical parameters against the datasheet before specifying.
Honeywell Honeywell Impact MCB Changeover Switch · 2P (DP) · 63 A · IH32PMCO63 · IH32PMCO63
SeriesImpact
Poles2P (DP)
Rated current63 A
Device typeMiniature circuit breaker (MCB)
Current rating63 A
Reference standardIS/IEC 60898-1
BrandHoneywell
Brand SKUIH32PMCO63
ELINER3K99P4M9
Sold asPer pc
Ratings as published by Honeywell (Honeywell price list). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which changeover switch do I need for a generator at home?

Use a changeover switch rated at least equal to your main incomer, with poles matching the supply (2 pole for single-phase, 4 pole for three-phase) so the neutral is also switched. This prevents generator power feeding back into the grid, which is dangerous for line workers, and installation should be done by a licensed electrician.

What is the difference between on-load and off-load changeover?

An on-load changeover switch is designed to transfer between mains and generator while current is flowing, while an off-load type must only be operated after the load is switched off. On-load types are safer and more convenient for most homes and shops; check the load rating on the product.

What is the difference between manual changeover and ATS?

A manual changeover needs someone to operate the handle when power fails, while an ATS (automatic transfer switch) senses mains failure and switches to the generator automatically, often also starting the DG set. ATS is used where unattended or quick changeover is needed.

Why does a changeover switch have a centre OFF position?

The centre OFF position ensures the load is fully disconnected from both sources before connecting to the other, so mains and generator can never be connected together. It is also used to isolate the load safely for maintenance.

How many poles does this changeover switch have?

The pole configuration of this changeover switch is 2P (DP). For generator backup, switching the neutral as well (2 pole on single-phase, 4 pole on three-phase) is the usual recommended practice.

Can I use a changeover switch for an inverter?

Yes, a changeover switch is often used to select between inverter output and mains, or to bypass the inverter during servicing. Size it for the circuits it will carry and make sure inverter output and mains are never paralleled.