C&S Electric On Load Changeover Switch · DM series · 4P · 400 A · Enclosed · E-CSCS400DM4COE-CSCS400DM4CO↓ 20% off
BrandC&S Electric
CategorySwitchgear
Specification4P · 400 A · Enclosed
Brand SKUE-CSCS400DM4CO
AvailabilityOn order · 2 to 3 weeks
Delivery8 to 15 business days after dispatch
C&S Electric· On order, 2 to 3 weeks
Visit the C&S Electric store

C&S Electric On Load Changeover Switch · DM series · 4P · 400 A · Enclosed · E-CSCS400DM4CO

Rating: 400 A
Execution: Enclosed
NEW added this week
$817.94/pc-20%
$1,022.43
Wholesale · 15+ units
$777.04 /pc
Add to cart
Buy now
On order: delivered in 2 to 3 weeks. We order it from C&S Electric for you once you place the order.
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$817.94 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
CHANGEOVER
FP (4 pole)
400 A
n/a
-
$817.94 /pc
Viewing above ↑
CHANGEOVER
FP (4 pole)
400 A
n/a
-
$603.40 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $777.04/pc on this product, applied automatically

C&S Electric on load changeover switch, DM series, 4 pole, 400 A, in a sheet steel enclosure, positions I-0-II, for switching a load between mains and generator supply. The operating handle and telescopic shaft come with the switch. C&S code E-CSCS400DM4CO.

As published by C&S Electric. Verify critical parameters against the datasheet before specifying.
C&S Electric C&S Electric On Load Changeover Switch · DM series · 4P · 400 A · Enclosed · E-CSCS400DM4CO · E-CSCS400DM4CO
Device typeOn load changeover switch
SeriesDM series
Poles4P (FP)
Rated current400 A
Rated voltage415 V AC
Reference standardIS/IEC 60947-3
executionSheet steel enclosed
short time withstand12 kA for 1 s
utilisation categoryAC-23A
Current rating400 A
BrandC&S Electric
Brand SKUE-CSCS400DM4CO
ELINEPHD4343R6
Sold asPer pc
noteenclosed version: Ith in enclosure applies where given
ui_v1000
uimp_kv12
standardIS/IEC 60947-3
icw_1s_ka12
positionsI-0-II
icm_peak_ka35
ac22a_415v_a400
ac23_kw_415v200
ac23a_415v_a400
ac23a_690v_a350
frequency_hz50 (brochure: 50/60)
ith_open_air_a400
ith_enclosure_a400
dims_4p_a1_x_b1_mmnull
breaking_ac23_415v_a3200
utilisation_categoryAC-23A
door_interlock_padlockyes (price list: door interlock and padlock facility up to 800A)
electrical_endurance_ops1000
mechanical_endurance_ops10000
rated_operational_voltage_v415
weight_4p_kg_with_handle_shaft4
Ratings as published by C&S Electric (C&S Electric price list, 22 Jan 2026; C&S Electric price list; C&S Electric brochure). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which changeover switch do I need for a generator at home?

Use a changeover switch rated at least equal to your main incomer, with poles matching the supply (2 pole for single-phase, 4 pole for three-phase) so the neutral is also switched. This prevents generator power feeding back into the grid, which is dangerous for line workers, and installation should be done by a licensed electrician.

What is the difference between on-load and off-load changeover?

An on-load changeover switch is designed to transfer between mains and generator while current is flowing, while an off-load type must only be operated after the load is switched off. On-load types are safer and more convenient for most homes and shops; check the load rating on the product.

What is the difference between manual changeover and ATS?

A manual changeover needs someone to operate the handle when power fails, while an ATS (automatic transfer switch) senses mains failure and switches to the generator automatically, often also starting the DG set. ATS is used where unattended or quick changeover is needed.

Why does a changeover switch have a centre OFF position?

The centre OFF position ensures the load is fully disconnected from both sources before connecting to the other, so mains and generator can never be connected together. It is also used to isolate the load safely for maintenance.

Can I use a changeover switch for an inverter?

Yes, a changeover switch is often used to select between inverter output and mains, or to bypass the inverter during servicing. Size it for the circuits it will carry and make sure inverter output and mains are never paralleled.