Schneider Harmony XB5N Push Button · 22 mm · Red mushroom 40 mm · Turn to release · 1 NC · IP65 · XB5AS542NXB5AS542N↓ 40% off1 / 7
BrandSchneider
CategoryIndustrial Control
Specification22 mm · 1 NC
Brand SKUXB5AS542N
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Harmony XB5N Push Button · 22 mm · Red mushroom 40 mm · Turn to release · 1 NC · IP65 · XB5AS542N

$4.89/pc-40%
$8.16
Wholesale · 15+ units
$4.80 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$4.89 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $4.80/pc on this product, applied automatically

This Harmony XB5N/XB7N, emergency shutdown 40mm mushroom modular red push button operates with a turn-to-release mechanism. It is easily installed into standard 22mm diameter cut-outs and connected with simple screw-clamp connections. It is clearly distinguishable visually at a distance thanks to a prominent 40mm mushroom shape. It is impact resistant, dust resistant, water resistant and vibration resistant, making it ideal for operation in harsh environments.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Harmony XB5N Push Button · 22 mm · Red mushroom 40 mm · Turn to release · 1 NC · IP65 · XB5AS542N · XB5AS542N
Rated current3 A
Ingress protectionIP65
Reference standardIEC 60947-5-4
Net weight0.072 kg
BrandSchneider
Brand SKUXB5AS542N
ELINEP7PJ4K7D2
Sold asPer pc
Depth78.5 mm
ResetTurn to release
Width40 mm
Height43 mm
Releaseturn to release
Operatorred mushroom 40 mm
Head typeMushroom
StandardsIEC 60947-5-4 · IEC 60947-1 · IEC 60947-5-1 · IS 13947-5-1
Fixing modeFixing nut recommended torque: 2.2 N.m (+/- 0.2 N.m)
Bezel materialDark grey plastic
Contacts usageStandard contacts
Trigger actionno
Operating forceNC changing electrical state · NO changing electrical state
Operating travel1.5 mm (NC changing electrical state) · 2.6 mm (NO changing electrical state) · 4.3 mm (total travel)
Operator profileRed mushroom Ø 40 mm, unmarked
Positive openingWith conforming to IEC 60947-5-1 appendix K
Range of productHarmony XB5N/XB7N
Type of operatorTurn to release mechanical latching
Contact operationSlow-break
Contacts materialSilver alloy (Ag/Ni)
Device short nameXB5N
Mounting diameter22.5 mm
Tightening torque0.8…1.2 N.m conforming to IEC 60947-1
Compatibility codeXB5
Device presentationComplete product
Shape of screw headCross compatible with Philips no 1 screwdriver · Cross compatible with pozidriv No 1 screwdriver · Slotted compatible with flat Ø 4 mm screwdriver · Slotted compatible with flat Ø 5.5 mm screwdriver
Overvoltage categoryClass II conforming to IEC 60536
Protective treatmentTH
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C · 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C · 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C · 1000000 cycles, DC-13, 0.2 A at
Mechanical durability300000 cycles
Product compatibilityZB5...N
Electrical reliabilityΛ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to IEC 60947-5-4 · Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to IEC 60947-5-4
Fixing collar materialPlastic
Product certificationsCE
Connections - terminalsScrew clamp terminals, = 1 x 0.22 mm² without cable end conforming to IEC 60947-1
Short-circuit protection10 A cartridge fuse type gG conforming to IEC 60947-5-1
Product or component typeEmergency switching off push-button
Shape of signaling unit headRound
Contacts type and composition1 NC
Sale per indivisible quantity20
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to IEC 60947-1
Terminals description ISO n°1(11-12)NC
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to IEC 60947-5-1 · 6 A at 120 V, AC-15, A600 conforming to IEC 60947-5-1 · 0.1 A at 600 V, DC-13, Q600 conforming to IEC 60947-5-1 · 0.27 A at 250 V, DC-13, Q600 conforming to IEC 60947-5-1 · 0.55 A at 125 V, DC-13, Q600 conforming to IEC 60947-5-1 · 1.2 A at 600 V, AC-15, A600 conforming to IEC 60947-5-1
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-25…70 °C
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
[Ith] conventional free air thermal current10 A conforming to IEC 60947-5-1
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
What hole size do these push buttons need?

Most industrial push buttons, pilot lights and selector switches use the standard 22 mm size, which needs a panel hole of about 22.3 mm, while some compact ranges use 16 mm. Check the cut-out size in the product datasheet before punching the panel door.

Which colours should I use for start, stop and indication?

Under IEC 60204-1, red is reserved for emergency stop and must not be used for start; start buttons are white (preferred), grey, black or green, yellow indicates an abnormal condition and blue a mandatory action such as reset. Pilot lights in Indian panels commonly use red, yellow and blue to indicate R, Y and B phase presence.

What is the difference between NO and NC contacts?

An NO (normally open) contact closes when the button is pressed and is used for start; an NC (normally closed) contact opens when pressed and is used for stop and emergency stop. Many push buttons accept additional contact blocks to add more NO or NC contacts.

What is the difference between a maintained and spring-return selector switch?

A maintained (stay-put) selector stays in the selected position, used for modes like Auto/Off/Manual, while a spring-return selector goes back to its default position when released, used for jog or momentary actions.

Is an emergency stop push button different from a normal stop button?

Yes. An emergency stop is a red mushroom head on a yellow background that latches when pressed and needs a twist or key to release, with a positive-opening NC contact (IEC 60947-5-1, IEC 60947-5-5). A normal stop button is momentary and should not be used for emergency stop duty.

No reviews yet