Schneider Acti9 iIL Modular Pilot Light · Red · 230-400 V AC · A9E18327A9E18327↓ 40% off1 / 2
BrandSchneider
CategorySwitchgear
SpecificationRed · 230-400 Vac
Brand SKUA9E18327
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Acti9 iIL Modular Pilot Light · Red · 230-400 V AC · A9E18327

$76.23/pc-40%
$127.04
Wholesale · 15+ units
$72.41 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$76.23 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $72.41/pc on this product, applied automatically

This Acti9 iIL is a three-phase voltage presence indicator light. The voltage is 230VAC to 400VAC. The 3 red light on the front face lights up to indicate that a voltage is present. The connection could be done with flexible copper cables or with ferrule cables from 0.5mm² up to 2 x 2.5mm². The tightening torque for the PZ1 screwdriver to connect screw connections is 1N.m. The connection could be done with rigid copper cables from 0.5mm² minimum up to 2 x 2.5mm2 maximum. It comes with staggered terminals to simplify the connection. The LED indication light maximum consumption per indicator light is 0.3W. The Operating frequency is 50Hz or 60Hz. The service life of the LED indicator light is 100000h of constant lightning efficiency. Because of the non-interchangeability of LEDs it is a maintenance-free device. The tropicalization is Treatment 2 (relative humidity 95% at 55°C). The degree of protection is IP20. The pollution degree is 3. The width in 9mm pitches is 2. The dimensions are (W) 18mm x (H) 82mm x (D) 68mm. The weight is 65g. The operating temperature is -35°C to + 70°C. The storage temperature is -40°C to + 80°C. This product complies with IEC/EN 60947-5-1 standard.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Acti9 iIL Modular Pilot Light · Red · 230-400 V AC · A9E18327 · A9E18327
Ingress protectionIP2
Reference standardIEC 73
ColourWhite (RAL 9003)
Device typeMiniature circuit breaker (MCB)
BrandSchneider
Brand SKUA9E18327
ELINEP36DM7629
Sold asPer pc
Depth69.5 mm
Width18 mm
Height82 mm
StandardsIEC 73 · IEC 1000-4
9 mm pitches2
Product nameActi9 iIL
Mounting modeFixed
Tropicalisation2
indicator light3 LEDs red, service life 100000 h of constant lighting efficiency (consumption 0.9 W)
Mounting supportSymmetrical DIN rail
Pollution degree3
range of productActi9
Device short nameiIL
Relative humidity95 % at 55 °C
Tightening torque1 N.m
Wire stripping length9 mm
IP degree of protectionIP2 · IPxx B
Product or component typeModular pilot light
[Us] rated supply voltage230...400 V AC at 50/60 Hz
Auxiliary connection terminalTunnel type terminal 1 cable(s) rigid 0.5 mm² · Tunnel type terminal 2 cable(s) rigid 2.5 mm² · Tunnel type terminal 1 cable(s) flexible 0.5 mm² · Tunnel type terminal 2 cable(s) flexible 2.5 mm² · Tunnel type terminal 2 cable(s) flexible with ferrule 2.5 mm²
Ambient air temperature for storage-40…80 °C
Ambient air temperature for operation-35…70 °C
Comb busbar and distribution block compatibilityUpside: ProDis
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.