🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Siemens Superswitch 3KL8 Switch Disconnector Fuse 63 A · TPN · Open Execution · DIN Type · 690 V AC · 3KL8151-3TA003KL8151-3TA00↓ 40% off
BrandSiemens
CategorySwitchgear
SpecificationSwitch disconnector fuse · 3KL8
Brand SKU3KL8151-3TA00
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Siemens· In stock
Visit the Siemens store

Siemens Superswitch 3KL8 Switch Disconnector Fuse 63 A · TPN · Open Execution · DIN Type · 690 V AC · 3KL8151-3TA00

$125.44/pc-40%
$209.08
Wholesale · 15+ units
$119.17 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$125.44 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $119.17/pc on this product, applied automatically

Siemens Superswitch 3KL8 Switch Disconnector Fuse 63 A (article 3KL8151-3TA00) is a switch disconnector fuse from Siemens, 3KL8 series, sold by Elume with a GST invoice and pan-India delivery. Key data: manufacturer product name SDF Size 1 63 A TPN DIN Open execution, ampere/current rating 63 A, no. of poles 3 Pole+N, type Open Execution, rated voltage (v) 690V AC, suitable for DIN Type. Priced at the Siemens India list price of 2026 (MRP before GST Rs 12,205), GST included in the price shown.

As published by Siemens. Verify critical parameters against the datasheet before specifying.
Siemens Siemens Superswitch 3KL8 Switch Disconnector Fuse 63 A · TPN · Open Execution · DIN Type · 690 V AC · 3KL8151-3TA00 · 3KL8151-3TA00
Device typeSwitch disconnector fuse
Series3KL8
Poles3P+N (TPN)
Rated current63 A
Current rating63 A
Reference standardIEC 60947-3
BrandSiemens
Brand SKU3KL8151-3TA00
ELINEP2HP6292P
Sold asPer pc
TypeOpen Execution
No. Of Poles3 Pole+N
Suitable ForDIN Type
Rated Voltage (V)690V AC
Ampere/Current Rating63 A
Manufacturer Product NameSDF Size 1 63 A TPN DIN Open execution
Ratings as published by Siemens (Siemens spec table; eleczo.com listing; Elume). Verify critical parameters against the datasheet before specifying.
Other Siemens ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
What is the difference between an isolator and an MCB?

An isolator (switch-disconnector) only switches the circuit on and off and does not trip on overload or short circuit, while an MCB provides protection. Isolators are used as main switches in DBs or near equipment for safe maintenance, and must be backed by a suitable MCB, MCCB or fuse.

Can I use an isolator as the main switch in my DB?

Yes, a DP isolator for single-phase or 4P isolator for three-phase is commonly used as the DB incomer, provided protection is given upstream (by the meter-side fuse or MCB) and on each outgoing circuit. Its current rating should be equal to or higher than the upstream protection rating.

Is this isolator safe to switch on load?

Switch-disconnectors to IS/IEC 60947-3 are rated for switching under load according to their utilisation category, such as AC-22 for mixed resistive and inductive loads or AC-23 for motor loads. Check the category on the product before using it to switch motors directly.

2 pole or 4 pole isolator - which one do I need?

Use 2 pole for single-phase supply (phase and neutral) and 4 pole for three-phase supply with neutral, so all live conductors are disconnected during maintenance. A 3 pole isolator is used where no neutral is switched, such as some motor feeders.

Can an isolator be locked off for maintenance?

Many isolators and rotary switch-disconnectors have a padlocking provision in the OFF position so no one can switch them on while work is in progress. Check for the lock-off feature if it is needed for your site's safety procedures.

No reviews yet