Schneider ComPacT NSX100 VigiPacT Vigi Add-On · 3P · ComPacT NSX 100/160 · 200 V AC to 440 V AC · 200-440 V AC 50/60 Hz · LV429488LV429488↓ 40% off
BrandSchneider
CategorySwitchgear
SpecificationComPacT NSX 100/160 · 200 VAC to 440 VAC · 30mA to 30 A · 3 poles
Brand SKULV429488
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider ComPacT NSX100 VigiPacT Vigi Add-On · 3P · ComPacT NSX 100/160 · 200 V AC to 440 V AC · 200-440 V AC 50/60 Hz · LV429488

$421.40/pc-40%
$702.33
Wholesale · 15+ units
$400.33 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$421.40 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $400.33/pc on this product, applied automatically

This is a Vigi add-on module for ComPact NSX 100/160 that provides an earth-leakage protection. It is used for 3 poles circuit breakers. The operational rated voltage is between 200 and 440 VAC 50/60 Hz. The earth-leakage sensitivity is adjustable from 30 mA to 30 A. It is installed directly on the device terminals and directly actuates the trip unit in case of earth-leakage default. This Vigi add-on module is self-powered internally by the distribution-system voltage, even is supplied by only 2 phases. It is compliant with IEC 60947-2 standard, annex B.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider ComPacT NSX100 VigiPacT Vigi Add-On · 3P · ComPacT NSX 100/160 · 200 V AC to 440 V AC · 200-440 V AC 50/60 Hz · LV429488 · LV429488
Poles3P (TP)
Rated current100 A
Reference standardIEC 60947-2
Device typeMiniature circuit breaker (MCB)
Current rating30 A
BrandSchneider
Brand SKULV429488
ELINEMR7PFJPMG
Sold asPer pc
StandardsIEC 60947-2
Network typeAC
Range of productComPacT NSX100...250 · ComPact NSX100...250
Device short nameVigiPacT
Network frequency50/60 Hz
Poles description3P
Device applicationWiring
[In] rated current100 A · 160 A
Range compatibilityComPacT ComPacT NSX100 circuit breaker · ComPacT ComPacT NSX160 circuit breaker · ComPact ComPact NSX100 circuit breaker · ComPact ComPact NSX160 circuit breaker
Overvoltage categoryIV
Maximum breaking time800 ms
Earth-leakage protectionWith
Earth-leakage sensitivity0.03 A for class A · 0.1 A for class A · 0.3 A for class A · 0.5 A for class A · 1 A for class A · 3 A for class A · 10 A for class AC · 30 A for class AC
Product or component typeVigi add-on
Earth-leakage protection classClass A · Class AC
[Ue] rated operational voltage200...440 V AC 50/60 Hz conforming to IEC 60947-2
Electrical shock protection classClass II
Residual earth-leakage sensitity adjustment typeAdjustable
Residual earth-leakage time delay adjustment typeAdjustable
[Δt] residual earth-leakage time delay adjustment0 ms · 60 ms · 150 ms · 300 ms · 500 ms · 800 ms · 1.2 s · 4 s
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.

No reviews yet