🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Siemens Sentron 3WA ACB · 4P · 4000 A · ETU600 LSING · Electrically operated draw-out · 3WA1240-3AF41-4EA43WA1240-3AF41-4EA4
BrandSiemens
CategorySwitchgear
SpecificationACB · price on request
Brand SKU3WA1240-3AF41-4EA4
AvailabilityOn order · confirmed within 7 days of your enquiry
DeliveryDelivery as per availability, confirmed within 7 days
Siemens· In stock
Visit the Siemens store

Siemens Sentron 3WA ACB · 4P · 4000 A · ETU600 LSING · Electrically operated draw-out · 3WA1240-3AF41-4EA4

Price on request
Availability and price confirmed within 7 days. Add it to your cart and check out: no payment is taken for this item, we email you the price and you decide. GST invoice as always.
Add to enquiry
Send enquiry
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
Price on request
Availability and price confirmed within 7 days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
✉️
Quoted on enquiry
Add it to your cart and check out: we confirm availability and price within 7 days, with no payment until you accept the quote

Siemens 3WA12 ACB (article 3WA1240-3AF41-4EA4) is a acb from Siemens, sold by Elume with a GST invoice and pan-India delivery. Price on request: add it to your cart and check out, and we confirm availability and price within 7 days by email.

As published by Siemens. Verify critical parameters against the datasheet before specifying.
Siemens Siemens Sentron 3WA ACB · 4P · 4000 A · ETU600 LSING · Electrically operated draw-out · 3WA1240-3AF41-4EA4 · 3WA1240-3AF41-4EA4
Device typeACB
Poles4P (FP)
Rated current4000 A
Current rating4000 A
Reference standardIS/IEC 60898-1
BrandSiemens
Brand SKU3WA1240-3AF41-4EA4
ELINEMJCRDKKGC
Sold asPer pc
DesignWithdrawable with guide frame
OperationElectrical, draw-out (EDO)
Trip unitETU600 LSING microprocessor based
Frame sizeII
Breaking capacityStandard, Ics = 100% Icu
Ratings as published by Siemens (Siemens spec table; Elume). Verify critical parameters against the datasheet before specifying.
Other Siemens ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When is an ACB used instead of an MCCB?

ACBs are used for very high currents, typically 630A up to 6300A, mostly as transformer or main LT panel incomers and bus couplers. They offer high short-time withstand (Icw), advanced releases and maintainability that MCCBs usually do not; both are covered by IS/IEC 60947-2.

What is the difference between fixed and draw-out ACB?

A fixed ACB is bolted directly into the panel, while a draw-out ACB sits in a cradle and can be racked out for testing or maintenance without disturbing the busbars. Draw-out is preferred for main incomers and critical supplies where quick replacement and safe isolation matter.

What is EDO and MDO in an ACB?

MDO (manually operated draw-out) is closed and opened by hand, while EDO (electrically operated draw-out) has a motor and closing/shunt coils for remote operation, auto changeover with DG sets and synchronising schemes. Choose EDO if the ACB will be part of an automatic transfer or SCADA/BMS system.

How do I select the ACB rating for my transformer?

As a rule of thumb, the incomer ACB is rated slightly above the transformer's full-load LT current (about 1.39A per kVA at 415V, so a 1000 kVA transformer needs roughly 1400A, usually a 1600A ACB). The breaking capacity must also exceed the transformer's LT fault level; a qualified electrical engineer should confirm the selection.

Does an ACB need regular maintenance?

Yes. ACBs need periodic inspection of contacts, arc chutes, mechanism lubrication and release testing as per the manufacturer's maintenance schedule, typically at least once a year or after a major fault trip. Maintenance should only be done by trained personnel with the ACB racked out and isolated.

No reviews yet