Schneider Acti9 iPRD40 SPD · 3P · A9L40300A9L40300↓ 40% off1 / 2
BrandSchneider
CategorySwitchgear
Specification3P
Brand SKUA9L40300
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Acti9 iPRD40 SPD · 3P · A9L40300

Poles: 3P
$266.65/pc-40%
$444.41
Wholesale · 15+ units
$253.33 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$266.65 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $253.33/pc on this product, applied automatically

This Acti9 iPRD40 surge arrester protects 3P installations. It allows quick replacement of damaged cartridges. This Type 2 device is recommended for high risk level and incoming panel board. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. This Acti9 iPRD40 is compatible with TT and TN-S earthing system. The Uc maximum continuous operating voltage in common mode (between phase and earth) is 350VAC. The Up maximum voltage protection level in common mode (between phase and earth) is 1.4kV. The Ue rated operational voltage is 230VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 54mm x (H) 85mm x (D) 69mm. The weight is 317g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standards.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Acti9 iPRD40 SPD · 3P · A9L40300 · A9L40300
Poles3P (TP)
Reference standardEN 61643-11:2012
Net weight0.317 kg
ColourWhite (RAL 9003)
Device typeMiniature circuit breaker (MCB)
BrandSchneider
Brand SKUA9L40300
ELINEMHH47299M
Sold asPer pc
Depth69 mm
Width54 mm
Height85 mm
StandardsEN 61643-11:2012 · IEC 61643-11:2011
9 mm pitches6
Product nameActi9 iPRD
Mounting modeClip-on (DIN rail)
Quality labelsKEMA-KEUR · NF
Earthing systemTN-C · IT 230
Range of productIPRD
Device short nameiPRD40
Poles description3P
Relative humidity5…95 %
Remote signallingWithout
Tightening torque2.5 N.m
Compatibility codeIPRD40
Device applicationDistribution
Operating altitude2000 m
Surge arrester typeElectrical distribution network
Product certificationsCE
Connections - terminalsTunnel type terminal (downside) 2.5…35 mm² · Tunnel type terminal (upside) 2.5…35 mm²
IK degree of protectionIK03 conforming to IEC 62262
Disconnector device typeAssociated circuit breaker iC60H 40 A curve C - Icu 15 kA · Associated circuit breaker IC60N 40 A curve C - Icu 10 kA · Associated circuit breaker NG125H 40 A curve C - Icu 36 kA · Associated circuit breaker NG125L 40 A curve C - Icu 50 kA · Associated circuit breaker NG125N 40 A curve C - Icu 25 kA · Associated fuse gG 63 A - Icu 15 kA · Associated fuse gG 80 A - Icu 50 kA
Maximum discharge currentCommon mode: 40 kA L/PE
Nominal discharge currentCommon mode: 15 kA (L/PE) · Common mode: 15 kA (N/PE)
Product or component typeSurge arrester with pluggable cartridge
Surge arrester class typeType 2
Surge arrester technologyMOV
[Ut] temporary overvoltage337 V L/N 5 s withstand · 1200 V N/PE 200 ms safe failure mode
[Ipe] Ground residual current0.003 mA · 0.6 mA
[Ue] rated operational voltage400 V AC (+/- 10 %) at 50/60 Hz
Ambient air temperature for storage-40…85 °C
Ambient air temperature for operation-25…60 °C
Maximum [Up] voltage protection levelCommon mode 1.4 kV type 2 L/PE
[Uc] maximum continuous operating voltageCommon mode: 350 V L/PE
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which type of SPD should I use for my home - Type 1 or Type 2?

For most homes and apartments, a Type 2 SPD in the main DB is the standard choice. Type 1 or combined Type 1+2 is used at the service entrance of independent houses in lightning-prone areas or buildings with external lightning protection (SPDs are covered by IS 16463 (Part 11), identical to IEC 61643-11).

Does an SPD need earthing?

Yes. An SPD diverts surge energy to earth, so it works only with a proper, low-resistance earth connection kept as short as possible. Without good earthing it gives little or no protection.

Will an SPD protect against high voltage from neutral failure?

No. SPDs are designed for short transient surges from lightning and switching, not sustained overvoltage such as from a broken neutral or poor supply. For that, use a voltage protection relay, an over/under voltage protector or stabilisers for sensitive equipment.

How do I know when the SPD needs replacing?

Most SPDs have an indicator window that turns from green to red when the protective element has reached end of life. Pluggable SPDs allow replacing only the cartridge; check the indicator periodically and after major thunderstorms.

Does an SPD need an MCB or fuse before it?

Yes, an SPD should have backup protection (MCB or fuse) as specified by the manufacturer, so a failed SPD can be safely disconnected without tripping the whole installation. The backup rating is usually listed in the SPD datasheet.

How many poles do I need for my supply?

The pole configuration of this SPD is 3P. A single-phase home typically uses a 1P+N or 2P SPD, and a three-phase supply uses 3P+N or 4P, so all live conductors are protected.

What do Imax, In and Up mean on an SPD?

Imax is the maximum surge current it can discharge once, In is the nominal current it can handle repeatedly, and Up is the voltage protection level (the let-through voltage), where lower is better. For 230 V homes, a Type 2 SPD with Imax around 40kA and a maximum continuous operating voltage (Uc) of 275 V or more is commonly used.