Lauritz Knudsen Encurve M Starter 25 A · 2 M · Magnesium Grey · CB95102MG25CB95102MG25↓ 13% off
BrandLauritz Knudsen
CategorySwitchgear
SpecificationMotor Starter · 25 A
Brand SKUCB95102MG25
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Lauritz Knudsen· In stock
Visit the Lauritz Knudsen store

Lauritz Knudsen Encurve M Starter 25 A · 2 M · Magnesium Grey · CB95102MG25

$20.58/pc-13%
$23.73
Wholesale · 15+ units
$19.55 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$20.58 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $19.55/pc on this product, applied automatically

Lauritz Knudsen Encurve M Starter 25 A · 2 M · Magnesium Grey is a motor starter from Lauritz Knudsen. It switches a motor on and off and protects it against overload. Key ratings: Rated current 25 A.

As published by Lauritz Knudsen. Verify critical parameters against the datasheet before specifying.
Lauritz Knudsen Lauritz Knudsen Encurve M Starter 25 A · 2 M · Magnesium Grey · CB95102MG25 · CB95102MG25
Device typeMotor starter
Rated current25 A
Current rating25 A
Reference standardIS/IEC 60898-1
BrandLauritz Knudsen
Brand SKUCB95102MG25
ELINEKRFKCRJ7H
Sold asPer pc
Ratings as published by Lauritz Knudsen (Lauritz Knudsen smartshop; Product name). Verify critical parameters against the datasheet before specifying.
Other Lauritz Knudsen ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.