Siemens Sentron 3VA2 MCCB 250 A · 4 Pole · 85 kA · Overload · Short Circuit & Earth Fault Settings · 3VA2225-6HM42-0AA03VA2225-6HM42-0AA0↓ 40% off1 / 5
BrandSiemens
CategorySwitchgear
SpecificationMCCB · 3VA2
Brand SKU3VA2225-6HM42-0AA0
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Siemens· In stock
Visit the Siemens store

Siemens Sentron 3VA2 MCCB 250 A · 4 Pole · 85 kA · Overload · Short Circuit & Earth Fault Settings · 3VA2225-6HM42-0AA0

$2,886.67/pc-40%
$4,811.12
Wholesale · 15+ units
$2,742.34 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$2,886.67 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCCB
FP (4 pole)
250 A
-
-
$476.27 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $2,742.34/pc on this product, applied automatically

Siemens Sentron 3VA2 MCCB 250 A (article 3VA2225-6HM42-0AA0) is a mccb from Siemens, 3VA2 series, sold by Elume with a GST invoice and pan-India delivery. Key data: manufacturer product name circuit breaker 3VA2 IEC Frame 250 breaking capacity class H Icu=85 kA @ 415 V 4-pole, line protection ETU330, LIG, In=250 A overload protection Ir=100 A...250 A short-circuit protection Ii=1.5...10 x In neutral conductor protection adjustable (OFF, 50%, 100%) ground-fault protection Ig=0.2...1 x In= tg=0.1/0.3s nut keeper kit, ampere/current rating 250 A, breaking capacity icu 85 kA, no. of poles 4 Pole, tripping type Microprocessor Trip Unit, protection type Overload, Short Circuit & Earth Fault, rated voltage (v) 415V AC. Priced at the Siemens India list price of 2026 (MRP before GST Rs 2,80,860), GST included in the price shown.

As published by Siemens. Verify critical parameters against the datasheet before specifying.
Siemens Siemens Sentron 3VA2 MCCB 250 A · 4 Pole · 85 kA · Overload · Short Circuit & Earth Fault Settings · 3VA2225-6HM42-0AA0 · 3VA2225-6HM42-0AA0
Device typeMCCB
Series3VA2
Poles4P (FP)
Rated current250 A
Breaking capacity85 kA
Current rating250 A
Reference standardIS/IEC 60898-1
BrandSiemens
Brand SKU3VA2225-6HM42-0AA0
ELINEKPPP7DP6J
Sold asPer pc
No. Of Poles4 Pole
Tripping TypeMicroprocessor Trip Unit
Protection TypeOverload, Short Circuit & Earth Fault
Rated Voltage (V)415V AC
Ampere/Current Rating250 A
Breaking Capacity Icu85 kA
Manufacturer Product Namecircuit breaker 3VA2 IEC Frame 250 breaking capacity class H Icu=85 kA @ 415 V 4-pole, line protection ETU330, LIG, In=250 A overload protection Ir=100 A...250 A short-circuit protection Ii=1.5...10 x In neutral conductor protection adjustable (OFF, 50%, 100%) ground-fault protection Ig=0.2...1 x In= tg=0.1/0.3s nut keeper kit
Ratings as published by Siemens (Siemens spec table; eleczo.com listing; Elume). Verify critical parameters against the datasheet before specifying.
Other Siemens ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.