🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider Acti9 Phase Segregated Distribution Board · 64 modules · split door · IP43 · flush mount · A9HPSG12MA9HPSG12M↓ 40% off
BrandSchneider
CategoryDB & Panels
Specification64 modules · split door · IP43 · flush mount
Brand SKUA9HPSG12M
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Acti9 Phase Segregated Distribution Board · 64 modules · split door · IP43 · flush mount · A9HPSG12M

Modules: 64 modules
$429.51/pc-40%
$715.84
Wholesale · 15+ units
$408.04 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$429.51 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $408.04/pc on this product, applied automatically

This Acti9 product is a surface or flush mounted 12 ways phase segregated distribution board with 3P or 4P MCCB as incomer provision. It allows the mounting of modular devices on 64 modules of 18mm such as RCCB (2P), and RCBO (2P). This distribution board comes with a reversible split metal door for door opening. The In rated current is 100A. It is provided with removable gland plates, removable centre plates, removable frame, grounding bar, neutral bar, busbar, cable, and rotary lock. The dimensions are (W) 926mm x (H) 607.2mm x (D) 135.6mm. The colour of the distribution board is white (RAL 9003). The weight is 25.45kg. The box, cable gland plate, and DIN rail are made of galvanized steel and CRCA is for the door, frame, and centre plate. The IP degree of protection is IP43 and IK09 with the split metal door. This distribution board complies with IS 8623-1 and 3, and IEC 61439-3 standards. It is certified with NABL certification.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Acti9 Phase Segregated Distribution Board · 64 modules · split door · IP43 · flush mount · A9HPSG12M · A9HPSG12M
Ways12 way
Rated current100 A
Ingress protectionIP43
ColourWhite (RAL 9003)
Reference standardIS 8623-1
Net weight25.45 kg
Enclosure typeDistribution board - SPN (single phase)
BrandSchneider
Brand SKUA9HPSG12M
ELINEKGRPGF39C
Sold asPer pc
DepthExternal : 135.6 mm
RangeActi9
WidthExternal: 926 mm
HeightExternal: 607.2 mm
StandardsIS 8623-1 · IS 8623-3 · IEC 61439-3
Product namePhase Segregated
Number of ways12 ways
Door opening sideReversible
Device applicationDistribution
Enclosure materialGalvanized steel box · Galvanized steel DIN rail · Galvanized steel cable gland plate · CRCA door · CRCA central plate · CRCA frame
Enclosure mountingFlush · Surface
Provided equipmentRemovable gland plates · Removable centre plates · Removable frame · Grounding bar · Neutral bar · Busbar · Cable · Rotary lock
[In] rated current100 A
Product certificationsNABL
Protection device typeMain incomer: molded case circuit breaker (MCCB) - 3P or 4P · Sub feeder: residual current circuit breaker (RCCB) - 2P (phase) · Sub feeder: residual current circuit breaker with overcurrent protection (RCBO) - 2P (phase)
IK degree of protectionIK09
IP degree of protectionIP43
Product or component typeDistribution board
Enclosure/cubicle descriptionSplit door enclosure
Total number of 18 mm modules64
Ratings as published by Schneider (Schneider spec table; se.com). Verify critical parameters against the datasheet before specifying.
Read: How Many Ways Should Your Distribution Board Have? 4, 8, 12 or 16 Way Explained →
What does 8 way or 12 way mean in a distribution board?
The number of single-module slots on the outgoing rail. Each single-pole MCB uses one way; wider devices like a double-pole RCCB use two or more. The usable circuit count is therefore the way count minus the width of incomer and protection devices.
How many ways do I need for a 2BHK?
Usually 8 to 12: two lighting circuits, two socket circuits, kitchen power, plus dedicated ways per AC and geyser, the RCCB's two ways, and spares. Buy 12 if the kitchen is appliance-heavy or an AC may be added later.
What is the difference between SPN and TPN distribution boards?
SPN boards serve single-phase (230 V) supplies with one phase busbar. TPN boards serve three-phase (415 V) supplies with three phase sections plus neutral, letting circuits balance across phases. Your electricity connection type decides which you need.
What does SPN mean in a distribution board?

SPN stands for Single Pole and Neutral, a DB for single-phase supply with a phase busbar, a neutral link and an earth bar. It is the standard DB for most Indian homes and small shops with single-phase connections.

How many ways do I need for a 2BHK or 3BHK flat?

Count one way per circuit (lighting, sockets, each AC, geyser, kitchen, etc.) plus incomer space, then add about 20-30% spare for future loads. A typical 2BHK uses around 8-12 ways and a 3BHK around 12-16 ways, but your circuit plan decides it.

Can I install an RCCB in this DB?

Most SPN DBs have incomer space for a DP MCB or isolator plus a 2-module RCCB, but this depends on the board. Check the incomer configuration, or choose an RCCB-ready DB if you want shock protection for all circuits.

Is flush mounting or surface mounting better?

Flush (concealed) DBs are recessed into the wall and suit new construction or renovation, while surface-mounted DBs are fixed on the wall and easier to retrofit. Measure the wall depth before choosing a flush DB.

Does the DB come with MCBs?

Most distribution boards are sold empty with busbar, neutral link and earth bar, and MCBs are bought separately. Check the package contents on the product page.

No reviews yet