🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Siemens Sinova 3KJ Manual Onload Changeover Switch 3150 A · 4 Pole · Open Execution · 415 V AC · 3KJ0560-4AA30-0AA03KJ0560-4AA30-0AA0↓ 40% off1 / 2
BrandSiemens
CategorySwitchgear
SpecificationChangeover switch · Sinova
Brand SKU3KJ0560-4AA30-0AA0
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Siemens· In stock
Visit the Siemens store

Siemens Sinova 3KJ Manual Onload Changeover Switch 3150 A · 4 Pole · Open Execution · 415 V AC · 3KJ0560-4AA30-0AA0

$10,135.21/pc-40%
$16,892.02
Wholesale · 15+ units
$9,628.45 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$10,135.21 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
CHANGEOVER
FP (4 pole)
3150 A
n/a
-
$8,567.64 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $9,628.45/pc on this product, applied automatically

Siemens Sinova 3KJ Manual Onload Changeover Switch 3150 A (article 3KJ0560-4AA30-0AA0) is a changeover switch from Siemens, Sinova series, sold by Elume with a GST invoice and pan-India delivery. Key data: manufacturer product name SINOVA, onload changeover switches 3KJ0, manually operated, size 5, 4-pole, in open execution, Iu: 3150 A, Ue AC: 415 V, Ie at AC-21 B at 415 V: 3150 A, screw mounting, front operating mechanism, at the left end, complete unit with door operating mechanism, Metallic handle, grey and black colour, flat terminal, ampere/current rating 3150 A, no. of poles 4 Pole, type Open Execution, rated voltage (v) 415V AC. Priced at the Siemens India list price of 2026 (MRP before GST Rs 9,86,110), GST included in the price shown.

As published by Siemens. Verify critical parameters against the datasheet before specifying.
Siemens Siemens Sinova 3KJ Manual Onload Changeover Switch 3150 A · 4 Pole · Open Execution · 415 V AC · 3KJ0560-4AA30-0AA0 · 3KJ0560-4AA30-0AA0
Device typeChangeover switch
SeriesSinova
Poles4P (FP)
Rated current3150 A
Current rating3150 A
Reference standardIS/IEC 60898-1
BrandSiemens
Brand SKU3KJ0560-4AA30-0AA0
ELINEKG32R2CM7
Sold asPer pc
TypeOpen Execution
No. Of Poles4 Pole
Rated Voltage (V)415V AC
Ampere/Current Rating3150 A
Manufacturer Product NameSINOVA, onload changeover switches 3KJ0, manually operated, size 5, 4-pole, in open execution, Iu: 3150 A, Ue AC: 415 V, Ie at AC-21 B at 415 V: 3150 A, screw mounting, front operating mechanism, at the left end, complete unit with door operating mechanism, Metallic handle, grey and black colour, flat terminal
Ratings as published by Siemens (Siemens spec table; eleczo.com listing; Elume). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which changeover switch do I need for a generator at home?

Use a changeover switch rated at least equal to your main incomer, with poles matching the supply (2 pole for single-phase, 4 pole for three-phase) so the neutral is also switched. This prevents generator power feeding back into the grid, which is dangerous for line workers, and installation should be done by a licensed electrician.

What is the difference between on-load and off-load changeover?

An on-load changeover switch is designed to transfer between mains and generator while current is flowing, while an off-load type must only be operated after the load is switched off. On-load types are safer and more convenient for most homes and shops; check the load rating on the product.

What is the difference between manual changeover and ATS?

A manual changeover needs someone to operate the handle when power fails, while an ATS (automatic transfer switch) senses mains failure and switches to the generator automatically, often also starting the DG set. ATS is used where unattended or quick changeover is needed.

Why does a changeover switch have a centre OFF position?

The centre OFF position ensures the load is fully disconnected from both sources before connecting to the other, so mains and generator can never be connected together. It is also used to isolate the load safely for maintenance.

Can I use a changeover switch for an inverter?

Yes, a changeover switch is often used to select between inverter output and mains, or to bypass the inverter during servicing. Size it for the circuits it will carry and make sure inverter output and mains are never paralleled.

No reviews yet