Schneider ComPacT NSX SD SDV OF SDE Auxiliary Contact Block · standard auxiliary contact29452↓ 40% off1 / 3
BrandSchneider
CategorySwitchgear
Specificationstandard auxiliary contact · circuit breaker status OF-SD-SDE-SDV · 1 low level single contact
Brand SKU29452
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider ComPacT NSX SD SDV OF SDE Auxiliary Contact Block · standard auxiliary contact

$20.45/pc-40%
$34.09
Wholesale · 15+ units
$19.44 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$20.45 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $19.44/pc on this product, applied automatically

It is a single low-level auxiliary contact that provides all the different indications remotely for Compact NSX, Compact NS, PowerPact Multistandard and EasyPact CVS circuit breakers. Remote status information are ON/OFF (OF), trip indication (SD) and fault-trip indication (SDE) for all circuit breakers types. The remote status information for trip indication due to an earth fault (SDV) is used for Compact NSX and PowerPact Multistandard. The contacts are installed in the device in dedicated slots. This auxiliary contact is a common point changeover type contact with 1 normally open contact and 1 normally closed contact. The rated current is 5A and the minimum load is 1MA at 4 VDC for utilization categories AC12/AC15/DC12/DC14. One device embeds 5 auxiliaries contact type. It complies with IEC 60947-5-1 standard.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider ComPacT NSX SD SDV OF SDE Auxiliary Contact Block · standard auxiliary contact · 29452
Device typeMiniature circuit breaker (MCB)
Reference standardIS/IEC 60898-1
BrandSchneider
Brand SKU29452
ELINEKF7CH37R9
Sold asPer pc
Fault typeGeneral electric fault
Minimum load1 mA at 4 V DC
Mounting modeClip-on
Local signallingON/OFF indication for open/close · Trip indicator for relay trip indicator · Fault trip for electrical fault
Device short nameSD · SDV · OF · SDE
Device applicationBreaker status monitoring
Range compatibilityComPact ComPact NS630b...1600 · ComPact ComPact NS1600b...3200 · ComPact ComPacT INS · ComPact Compact INV · ComPact ComPact NSX · EasyPact EasyPact CVS · PowerPact PowerPact Multistandard · ComPact ComPact NSX DC
Breaking capacity (A)AC-12: 5 A at 24 V AC 50/60 Hz · AC-12: 5 A at 48 V AC 50/60 Hz · AC-12: 5 A at 110 V AC 50/60 Hz · AC-12: 5 A at 220/240 V AC 50/60 Hz · AC-12: 5 A at 380/440 V AC 50/60 Hz · AC-12: 5 A at 480 V AC 50/60 Hz · AC-15: 3 A at 24 V AC 50/60 Hz · AC-15: 3 A at 48 V AC 50/60 Hz · AC-15: 2.5 A at 110 V AC 50/60 Hz · AC-15: 2 A at 220/240 V AC 50/60 Hz · AC-15: 1.5 A at 380/440 V AC 50/60 Hz · AC-15: 1 A
Auxiliary contacts typeLow level
Product or component typeAuxiliary contact
Signal contacts composition1 NO/NC
Accessory / separate part categorySpare part for Compact NS630b...1600 · Spare part for Compact NS1600b...3200
[Ith] conventional free air thermal current5 A
Other Schneider ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
No reviews yet