Schneider Acti9 iPRC SPD · A9L16337A9L16337↓ 40% off
BrandSchneider
CategorySwitchgear
SpecificationiPRC - 2 poles - 0.45 A - 130 V AC
Brand SKUA9L16337
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Acti9 iPRC SPD · A9L16337

$157.08/pc-40%
$261.81
Wholesale · 15+ units
$149.23 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$157.08 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $149.23/pc on this product, applied automatically

This Acti9 iPRC product is a surge arrester protecting against overvoltage related to lightning strikes. The DC power supply inputs up to 53V and AC power supply inputs up to 37V. The iPRI surge arrester protects the measuring instrument and PLC "sensor" inputs. It protects for 2 low-current lines without common potential or 4 lines with common reference potential. The input current must not exceed 300mA. The Uc maximum continuous operating voltage in common mode (between neutral and earth) is 130VAC or 185VDC. The Uc maximum continuous operating voltage in differential mode (between pgase and neutral) is 130VAC or 185VAC. The Up Voltage protection level in differential mode (between phase and neutral) is 160V. The Up Voltage protection level in common mode (between phase and earth) is 200V. The Ue rated operational voltage is 130VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 18mm x (H) 90mm x (D) 66mm. The weight is 25g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Acti9 iPRC SPD · A9L16337 · A9L16337
Rated current0.45 A
Ingress protectionIP40 (modular enclosure)· IP20
Reference standardEN 61643-21
Net weight0.025 kg
ColourWhite
Device typeMiniature circuit breaker (MCB)
Current rating45 A
BrandSchneider
Brand SKUA9L16337
ELINEKCPM97R4H
Sold asPer pc
Depth66 mm
Width18 mm
Height90 mm
MaterialPA6
StandardsEN 61643-21 · IEC 61643-21
9 mm pitches2
Product nameActi9 iPRC
Mounting modeFixed
Response time< 500 ns
Mounting support35 mm symmetrical DIN rail
range of productActi9
Device short nameiPRC
Relative humidity5…90 %
Remote signallingWithout
Tightening torque0.8 N.m
Operating altitude2000 m
[In] rated current0.45 A at 45 °C
Surge arrester typeTelecom protection
Output voltage limitsCommon mode: < 300 V at 1 kV/µs · Differential mode: < 300 V at 1 kV/µs
Wire stripping length8 mm
Product certificationsxDSL compliance
[Iimp] impulse current100 A
Connections - terminalsScrew clamp terminal0.2…4 mm² rigid · Screw clamp terminal0.2…2.5 mm² flexible · Screw clamp terminal0.2…2.5 mm² flexible with ferrule
IK degree of protectionIK05 conforming to IEC 62262
IP degree of protectionIP40 (modular enclosure) conforming to IEC 60529 · IP20 conforming to IEC 60529
Nominal discharge currentCommon mode: 10 kA (L/PE) · Differential mode: 10 kA (L/N)
Number of protected lines2
Product or component typeSurge arrester
Surge arrester technologyGDT + diode
[I total] discharge current10 kA
[Ue] rated operational voltage130 V AC
Ambient air temperature for storage-40…85 °C
Ambient air temperature for operation-25…60 °C
Maximum [Up] voltage protection levelDifferential mode 160 V type 2 L/N · Common mode 200 V type 2 L/PE
[Uc] maximum continuous operating voltageCommon mode: 130 V AC L/PE · Common mode: 185 V DC L/PE · Differential mode: 130 V AC L/N · Differential mode: 185 V DC L/N
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which type of SPD should I use for my home - Type 1 or Type 2?

For most homes and apartments, a Type 2 SPD in the main DB is the standard choice. Type 1 or combined Type 1+2 is used at the service entrance of independent houses in lightning-prone areas or buildings with external lightning protection (SPDs are covered by IS 16463 (Part 11), identical to IEC 61643-11).

Does an SPD need earthing?

Yes. An SPD diverts surge energy to earth, so it works only with a proper, low-resistance earth connection kept as short as possible. Without good earthing it gives little or no protection.

Will an SPD protect against high voltage from neutral failure?

No. SPDs are designed for short transient surges from lightning and switching, not sustained overvoltage such as from a broken neutral or poor supply. For that, use a voltage protection relay, an over/under voltage protector or stabilisers for sensitive equipment.

How do I know when the SPD needs replacing?

Most SPDs have an indicator window that turns from green to red when the protective element has reached end of life. Pluggable SPDs allow replacing only the cartridge; check the indicator periodically and after major thunderstorms.

Does an SPD need an MCB or fuse before it?

Yes, an SPD should have backup protection (MCB or fuse) as specified by the manufacturer, so a failed SPD can be safely disconnected without tripping the whole installation. The backup rating is usually listed in the SPD datasheet.

What do Imax, In and Up mean on an SPD?

Imax is the maximum surge current it can discharge once, In is the nominal current it can handle repeatedly, and Up is the voltage protection level (the let-through voltage), where lower is better. For 230 V homes, a Type 2 SPD with Imax around 40kA and a maximum continuous operating voltage (Uc) of 275 V or more is commonly used.