Lauritz Knudsen Exora RCCB · 4P (FP) · 63 A · 100 mA · Type AC · BG406310BG406310↓ 27% off
BrandLauritz Knudsen
CategorySwitchgear
SpecificationExora RCCB · 4P (FP) · 63 A · 100 mA · Type AC · 4 modules · current operated (CBCT)
Brand SKUBG406310
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Lauritz Knudsen· In stock
Visit the Lauritz Knudsen store

Lauritz Knudsen Exora RCCB · 4P (FP) · 63 A · 100 mA · Type AC · BG406310

$79.80/pc-27%
$109.07
Wholesale · 15+ units
$75.81 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$79.80 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCCB · Type AC
4P / 3P+N (three phase)
63 A
n/a
100 mA
$79.80 /pc
Viewing above ↑
RCCB · Type AC
4P / 3P+N (three phase)
63 A
n/a
100 mA
$44.12 /pc
RCCB · Type AC
4P / 3P+N (three phase)
63 A
n/a
100 mA
$47.79 /pc
RCCB · Type AC
4P / 3P+N (three phase)
63 A
n/a
100 mA
$47.92 /pc
RCCB · Type AC
4P / 3P+N (three phase)
63 A
n/a
100 mA
$48.79 /pc
RCCB · Type AC
4P / 3P+N (three phase)
63 A
n/a
100 mA
$58.15 /pc
RCCB
4P / 3P+N (three phase)
63 A
n/a
100 mA
$65.57 /pc
RCCB
4P / 3P+N (three phase)
63 A
n/a
100 mA
$87.51 /pc
RCCB · Type AC
4P / 3P+N (three phase)
63 A
n/a
100 mA
$97.07 /pc
RCCB · Type AC
4P / 3P+N (three phase)
63 A
n/a
100 mA
$126.83 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $75.81/pc on this product, applied automatically

Exora RCCBs from Lauritz Knudsen, DP and FP, 25 A to 100 A, 30 / 100 / 300 mA sensitivity.

  • Conforms to IS 12640 (Part 1) / IEC 61008-1
  • DP and FP versions from 25 A to 100 A with 30 mA, 100 mA and 300 mA sensitivity
  • Truly current operated: operates even at nominal voltage
  • Operates on the core balance current transformer (CBCT) principle
  • Advanced neutral mechanism
As published by Lauritz Knudsen. Verify critical parameters against the datasheet before specifying.
Lauritz Knudsen Lauritz Knudsen Exora RCCB · 4P (FP) · 63 A · 100 mA · Type AC · BG406310 · BG406310
Device typeResidual current circuit breaker (RCCB)
SeriesExora
Poles4P (FP)
Rated current63 A
Sensitivity (IΔn)100 mA
RCCB typeType AC
Rated voltage240 / 415 V AC
Width4 modules
Reference standardIS 12640 (Part 1), IEC 61008-1
Current rating63 A
Sensitivity100 mA
BrandLauritz Knudsen
Brand SKUBG406310
ELINEK2J3HRMF7
Sold asPer pc
Ratings as published by Lauritz Knudsen (Lauritz Knudsen price list Aug 2026). Verify critical parameters against the datasheet before specifying.
The letter after the sensitivity says which earth-fault currents the breaker can sense. Every type trips on a plain AC leak; the higher types also catch the leaks electronics produce. Same rating, different type, different price.
Type AC
THIS UNIT
Senses sinusoidal AC leakage only. Enough for lighting, geysers, heaters and plain socket circuits.
Type A
Senses AC and pulsating DC leakage, the kind inverter air conditioners, washing machines, UPS units, solar inverters and EV chargers produce. A Type AC unit can stay blind to those faults. Covers everything Type AC does. The safe default for a modern home.
Type A APR
Type A with high immunity to nuisance tripping: a short delay rides through lightning surges and switching transients. For circuits where a false trip costs more than the delay: servers, refrigeration, long cable runs.
Sensitivity is a separate choice: 30 mA protects people from shock; 100 mA and 300 mA units are for fire protection or as an upstream main. Type definitions per IEC/EN 61008 and 61009.
Other Lauritz Knudsen ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Is 30mA or 100mA RCCB right for home?

For protecting people from shock, use 30mA on circuits feeding sockets, bathrooms, kitchens and outdoor points. 100mA or 300mA RCCBs are mainly for fire protection and are often used upstream as a main device, with 30mA protection on the final circuits.

Does an RCCB need an MCB with it?

Yes. An RCCB only detects earth leakage and does not protect against overload or short circuit, so it must be backed up by an MCB or fuse of a rating given in the manufacturer's data (RCCBs are covered by IS 12640 (Part 1)).

Why does my RCCB keep tripping?

Common causes are genuine leakage from a faulty appliance (often a geyser element, pump or washing machine), moisture in wiring, neutral of one circuit being shared with another, or many electronic loads adding up their small leakages. Switch off all MCBs and turn them on one by one to find the culprit circuit, and have an electrician test insulation; never bypass the RCCB.

What is the difference between Type AC and Type A RCCB?

Type AC detects only sinusoidal AC leakage, while Type A also detects pulsating DC leakage produced by electronic loads like inverter ACs, washing machines, induction cooktops and LED drivers. Type A is the safer choice for modern homes with many electronic appliances; EV chargers and VFDs may need Type B or a charger with built-in DC detection.

How often should I press the test button?

Manufacturers commonly recommend pressing the test button regularly, often once a month; check the interval in the product's instructions. The RCCB should trip immediately, and if it does not, have an electrician check and replace it.

What current rating RCCB do I need - 25A, 40A or 63A?

The RCCB's rated current should be equal to or higher than the MCB or main switch feeding it, because it must carry the full load current. Many Indian homes use 40A or 63A RCCBs at the incomer; for a single circuit, 25A is common.