Schneider Acti9 PRD1 25r SPD · 3P16331↓ 40% off
BrandSchneider
CategorySwitchgear
Brand SKU16331
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Acti9 PRD1 25r SPD · 3P

Poles: 3P
$776.11/pc-40%
$1,293.50
Wholesale · 15+ units
$737.30 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$776.11 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $737.30/pc on this product, applied automatically

This Acti9 PRD1 is a modular surge arrester protecting 3P electrical installations against direct lightning strikes. The Imax maximum discharge current is 40kA .The In nominal discharge current is 25kA. The Type 1 surge arrester is recommended for electrical installations in the service sector and industrial buildings protected by a lightning conductor. It also provides type 2 protection and protect the electrical installation by finely clipping the lightning wave overvoltage. The surge arresters with "r" indication have remote transfer of the information "Cartridge to be replaced". The Uc maximum continuous operating voltage in common mode (between phase and earth) is 350VAC. The Up Voltage protection level in common mode (between phase and earth) is 1.5kV. The Ue rated operational voltage is 230VAC +/- 10%. The product colour is anthracite grey (RAL7016).The dimensions are (W) 108mm x (H) 90mm x (D) 71mm. The weight is 1.010kg. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 80°C. This product is compliant with EN 61643-11 and IEC 61643-11 standards.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Acti9 PRD1 25r SPD · 3P · 16331
Poles3P (TP)
Reference standardEN 61643-11:2012
Net weight1.01 kg
ColourAnthracite grey (RAL 7016)
Device typeMiniature circuit breaker (MCB)
BrandSchneider
Brand SKU16331
ELINEJJCGHG9D6
Sold asPer pc
Depth71 mm
Width108 mm
Height90 mm
MaterialPBT (polybutylene terephthalate)
StandardsEN 61643-11:2012 · IEC 61643-11:2011
9 mm pitches12
Product nameActi9 PRD1
Mounting modeClip-on (DIN rail)
Market segmentSmall commercial
Quality labelsKEMA-KEUR
Earthing systemTN-C
Impulse current25 kA
Range of productPRD1
Device short namePRD1 25r
Poles description3P
Relative humidity5…95 %
Remote signallingWith
Tightening torque4.5 N.m
Compatibility codePRD1_25r
Device applicationDistribution
Operating altitude2000 m
Surge arrester typeElectrical distribution network
[Ifi] follow current25 kA differential mode L/N · 3 kA differential mode L/N · 100 A common mode N/PE
Product certificationsCE
[Iimp] impulse currentCommon mode: 25 kA L/PE 12.5 A.s
Connections - terminalsTunnel type terminal (top or bottom) 10…35 mm² rigid · Tunnel type terminal (top or bottom) 10…25 mm² flexible
IK degree of protectionIK05 conforming to IEC 62262
Short-circuit withstand25 kA
Disconnector device typeAssociated fuse gG 315 A up to Isc = 25 kA · Associated circuit breaker NSXm 100E TM-D up to Isc = 16 kA · Associated circuit breaker NSXm 100B TM-D up to Isc = 25 kA · Associated circuit breaker Compact NSX100B TM-D up to Isc = 25 kA
Maximum discharge currentCommon mode: 40 kA L/PE
Nominal discharge currentCommon mode: 25 kA (L/PE)
Product or component typeSurge arrester with pluggable cartridge
Surge arrester class typeType 1 + 2
Surge arrester technologyMOV · Spark gap
Signalling circuit voltage1 A/250 V AC · 1 A/30 V DC
[Ut] temporary overvoltage1200 V N/PE 200 ms withstand · 415 V L/N 5 s withstand · 440 V L/N 7200 s safe failure mode
Signal contacts composition1 SD (1 C/O)
[Ue] rated operational voltage400 V AC (+/- 10 %) at 50/60 Hz
Ambient air temperature for storage-40…80 °C
Ambient air temperature for operation-25…60 °C
Maximum [Up] voltage protection levelCommon mode 1.5 kV type 2 L/PE
[Uc] maximum continuous operating voltageCommon mode: 350 V L/PE
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which type of SPD should I use for my home - Type 1 or Type 2?

For most homes and apartments, a Type 2 SPD in the main DB is the standard choice. Type 1 or combined Type 1+2 is used at the service entrance of independent houses in lightning-prone areas or buildings with external lightning protection (SPDs are covered by IS 16463 (Part 11), identical to IEC 61643-11).

Does an SPD need earthing?

Yes. An SPD diverts surge energy to earth, so it works only with a proper, low-resistance earth connection kept as short as possible. Without good earthing it gives little or no protection.

Will an SPD protect against high voltage from neutral failure?

No. SPDs are designed for short transient surges from lightning and switching, not sustained overvoltage such as from a broken neutral or poor supply. For that, use a voltage protection relay, an over/under voltage protector or stabilisers for sensitive equipment.

How do I know when the SPD needs replacing?

Most SPDs have an indicator window that turns from green to red when the protective element has reached end of life. Pluggable SPDs allow replacing only the cartridge; check the indicator periodically and after major thunderstorms.

Does an SPD need an MCB or fuse before it?

Yes, an SPD should have backup protection (MCB or fuse) as specified by the manufacturer, so a failed SPD can be safely disconnected without tripping the whole installation. The backup rating is usually listed in the SPD datasheet.

How many poles do I need for my supply?

The pole configuration of this SPD is 3P. A single-phase home typically uses a 1P+N or 2P SPD, and a three-phase supply uses 3P+N or 4P, so all live conductors are protected.

What do Imax, In and Up mean on an SPD?

Imax is the maximum surge current it can discharge once, In is the nominal current it can handle repeatedly, and Up is the voltage protection level (the let-through voltage), where lower is better. For 230 V homes, a Type 2 SPD with Imax around 40kA and a maximum continuous operating voltage (Uc) of 275 V or more is commonly used.

No reviews yet