🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider VigiPacT GA300 Earth Leakage Current Sensor · closed toroid A type50442↓ 40% off1 / 2
BrandSchneider
CategorySwitchgear
Specificationclosed toroid A type · for Vigirex and Vigilhom · inner diameter 300 mm · rated current 630 A
Brand SKU50442
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider VigiPacT GA300 Earth Leakage Current Sensor · closed toroid A type

$1,064.28/pc-40%
$1,773.80
Wholesale · 15+ units
$1,011.05 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$1,064.28 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $1,011.05/pc on this product, applied automatically

This toroid is dedicated to Vigilohm Insulation Fault locators, and to VigiPacT type A residual current protection and monitoring relays. It allows the monitoring of the injected component from Vigilohm Insulation Monitor, and the measurement of a current rating up to 630A for VigiPacT monitoring and protection relays. The transformer ratio is 1/1000. The inner diameter of the toroid is 300 millimeters and the weight is 2.280kg. The cables must be centered within the toroid and the diameter represented by all these cables should not exceed 150 millimeters. The maximum cross section per phase (R, S, T, N) is 2 cables of 240mm² for a copper conductor.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider VigiPacT GA300 Earth Leakage Current Sensor · closed toroid A type · 50442
Rated current630 A
Ingress protectionBody: IP30
Reference standardIEC 60947-2
Net weight2.28 kg
Device typeMiniature circuit breaker (MCB)
Current rating630 A
BrandSchneider
Brand SKU50442
ELINEJ9HFKK33C
Sold asPer pc
Depth46 mm
RangeVigiPacT
WidthOutside: 390 mm
HeightOutside: 360 mm
Diameter291 mm inner:
StandardsIEC 60947-2
Mounting modeFixed (cables)
Pollution degreeLevel 3 conforming to IEC 60664-1
Device short nameGA300
Network frequency50/60 Hz · 400 Hz
Transformer ratio1/1000
Device applicationEquipment monitoring and control
Range compatibilityVigiPacT RH10M residual current protection relay · VigiPacT RH10P residual current protection relay · VigiPacT RH21M residual current protection relay · VigiPacT RH21P residual current protection relay · VigiPacT RH68M residual current protection relay · VigiPacT RH86M residual current protection relay · VigiPacT RH86P residual current protection relay · VigiPacT RH99M residual current protection
current sensor typeA type closed toroid
Overvoltage categoryIV
Product certificationsCE
Connections - terminalsScrew connection 0.22…2.5 mm²
IP degree of protectionBody: IP30 · Connectors: IP20
Product or component typeEarth leakage current sensor
Environmental characteristicExposure to damp heat in service: category C2: 48 hours conforming to IEC 60068-2-56 · Exposure to damp heat not in service (25...55 °C, RH 95 %) : 28 cycles conforming to IEC 60068-2-30 · Salt mist: Kb/2 conforming to IEC 60068-2-52
[Ui] rated insulation voltage1000 V
[Ie] rated operational current630 A
Ambient air temperature for storage-55…85 °C
Ambient air temperature for operation-35…70 °C
[Uimp] rated impulse withstand voltage12 kV
Residual short-circuit withstand current85 kA / 0.5 s conforming to IEC 60947-2
[Icw] rated short-time withstand current85 kA for 0.5 s
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
No reviews yet