Schneider Mureva Enclosure · 5 modules · transparent · IP65 · surface mount13178↓ 40% off1 / 2
BrandSchneider
CategoryDB & Panels
Brand SKU13178
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Mureva Enclosure · 5 modules · transparent · IP65 · surface mount

Modules: 5 modules
$61.75/pc-40%
$102.91
Wholesale · 15+ units
$58.65 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$61.75 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $58.65/pc on this product, applied automatically

This Kaedra weatherproof enclosure is a surface mounted enclosure for industrial power outlet. It is composed of 1 row of 5 modules of 18mm. It can accomodate all types of modular switchgear. There are 2 openings for industrial or domestic power outlets, buttons or indicator lights. The IP degree of protection is IP65. This enclosure is dedicated to indoor or outdoor waterproof installation. It is provided with a transparent green door for modular devices. The colour of enclosure is light grey (RAL 7035). It is intended for installation in residential, small buildings and industry. The cables can enter by the top or the bottom of the enclosure via 3 pre-cutouts. It is equipped with a back plate and a front cover with notch. It is provided with DIN rail, 2 plates for 65x85mm power outlets and 1 plate for push-button control. It comes with 1 terminal block. The terminal block has 4 outgoers (2x10mm² + 2x16mm²). A marking kit are also delivered within the product. The electrical insulation class is class II (double insulated). The overvoltage category is class II. The dissipated power is 12W. The In rated current is up to 63A. This product complies with IEC 61439-3 standard. The dimen

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Mureva Enclosure · 5 modules · transparent · IP65 · surface mount · 13178
Rated current63 A
Ingress protectionIP65
ColourDoor: transparent green
Reference standardIEC 60670-1
Net weight1.4 kg
Enclosure typeDistribution board - SPN (single phase)
BrandSchneider
Brand SKU13178
ELINEH7M7J9G33
Sold asPer pc
Depth160 mm
RangeMureva
Width138 mm
Height460 mm
StandardsIEC 60670-1 · IEC 60670-24 · EN 62262 · EN 50262 · IEC 60695-2-1
9 mm pitches10
Product nameMureva Enclosure
Type of railDIN
Base dimension90 x 100 mm
Internal depth91 mm
Fire resistance650 °C conforming to IEC 60695-2-1
Number of plates1 for push-button controls · 2 for 65 x 85 power outlets
Enclosure materialHousing: self-extinguishing polymer
Enclosure mountingSurface
Provided equipment1 plate for push-button control · 2 plate for 65 x 85 power outlet
[In] rated current63 A
Type of front coverTransparent
Overvoltage categoryII
Power dissipation in W12 W
IK degree of protectionIK09 conforming to EN 50102
IP degree of protectionIP65 conforming to IEC 60529
Number of horizontal rows1
Product or component typeWeatherproof enclosure
Mounting plate descriptionWithout mounting plate
Electrical insulation classClass II · Double insulation
Locking options descriptionOptional keylock
Number of pre-cutouts PG ISO3
Total number of 18 mm modules5
Number of 18 mm modules per row5
Number of openings of interface2
Environmental characteristics (UV)UV resistant: class 3 conforming to ISO 4582:2010 · Ultraviolet degradation test conforming to ISO 4892-2:2013
Ambient air temperature for operation-25…40 °C
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Read: How Many Ways Should Your Distribution Board Have? 4, 8, 12 or 16 Way Explained →
What does 8 way or 12 way mean in a distribution board?
The number of single-module slots on the outgoing rail. Each single-pole MCB uses one way; wider devices like a double-pole RCCB use two or more. The usable circuit count is therefore the way count minus the width of incomer and protection devices.
How many ways do I need for a 2BHK?
Usually 8 to 12: two lighting circuits, two socket circuits, kitchen power, plus dedicated ways per AC and geyser, the RCCB's two ways, and spares. Buy 12 if the kitchen is appliance-heavy or an AC may be added later.
What is the difference between SPN and TPN distribution boards?
SPN boards serve single-phase (230 V) supplies with one phase busbar. TPN boards serve three-phase (415 V) supplies with three phase sections plus neutral, letting circuits balance across phases. Your electricity connection type decides which you need.
What IP rating do I need for an outdoor enclosure?

For outdoor or dusty, wet locations, use at least IP55, and IP65 or IP66 where direct water jets or heavy dust are expected (IP ratings follow IS/IEC 60529). Indoor clean areas usually need only IP42 to IP54.

Should I choose metal or polycarbonate enclosure?

CRCA steel with powder coating is strong and widely used indoors, stainless steel suits corrosive or food-industry areas, and polycarbonate or ABS is light, rust-proof and good for outdoor or coastal sites. Choose based on environment, impact risk and heat inside the enclosure.

How do I size an enclosure for my components?

Lay out all components with clearance for wiring, then add about 20-30% extra space for heat dissipation and future additions. Also check the depth needed for MCCBs, VFDs and cable bending.

Does the enclosure come with a mounting plate and gland plate?

Most wall-mounted enclosures include a mounting plate for components and a removable gland plate for cable entry, but some are sold without them. Check the product contents before ordering.

Do I need ventilation or a fan in my panel?

Heat-generating equipment like VFDs, transformers and power supplies may need louvres with filters, fans or air conditioners to keep internal temperature within component limits. Calculate the heat loss from component datasheets or consult your panel builder.

How is the enclosure earthed?

Enclosures usually have an earthing stud on the body and door; the door should be connected to the body with an earthing strap. All metal parts must be bonded to the protective earth of the installation.

No reviews yet