Schneider EasyPact CVS400N MCCB · 4P · 400 A · 50 kA · TM-D · LV540319LV540319↓ 40% off1 / 5
BrandSchneider
CategorySwitchgear
Specification4P · 400 A · 50 kA · TM-D
Brand SKULV540319
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider EasyPact CVS400N MCCB · 4P · 400 A · 50 kA · TM-D · LV540319

$826.65/pc-40%
$1,377.75
Wholesale · 15+ units
$785.32 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$826.65 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCCB
FP (4 pole)
400 A
-
50 kA
$826.65 /pc
Viewing above ↑
MCCB
FP (4 pole)
400 A
-
50 kA
$656.47 /pc
MCCB
FP (4 pole)
400 A
-
-
$689.75 /pc
MCCB
FP (4 pole)
400 A
-
50 kA
$791.83 /pc
MCCB
FP (4 pole)
400 A
-
50 kA
$920.00 /pc
MCCB
FP (4 pole)
400 A
-
50 kA
$1,107.76 /pc
MCCB
FP (4 pole)
400 A
-
50 kA
$1,118.51 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $785.32/pc on this product, applied automatically

EasyPact CVS400N is a 4 poles 3d fixed circuit breaker with a high level of performance and cost-saving functionality. It is an optimal choice for small and medium-sized buildings protection applications. The breaking capacity (Icu) is 50kA rms at 415VAC 50/60Hz. The operational voltage is 440VAC 50/60Hz. This product embeds a 400A rating thermal-magnetic trip unit (TMD). TMD trip unit provides an adjustable thermal overload protection and a fixed magnetic protection. This 4 poles version (185mm x 255mm x 110mm) comes with a variety of optional functions and accessories. EasyPact CVS400N is compliant with international standards (IEC 60947, CCC, EAC). It can be installed in class II insulation switchboards as it is a class II front face device (IEC 60664-1).

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider EasyPact CVS400N MCCB · 4P · 400 A · 50 kA · TM-D · LV540319 · LV540319
Poles4P (FP)
Rated current400 A
Breaking capacity50 kA
Ingress protectionIP40
Reference standardEN 60947-2
Net weight6.3 kg
Device typeMiniature circuit breaker (MCB)
Current rating400 A
BrandSchneider
Brand SKULV540319
ELINEG99PRM6JJ
Sold asPer pc
Depth110 mm
RangeEasyPact
Width185 mm
Height255 mm
StandardsEN 60947-2 · IEC 60947-2
Control typeToggle
Network typeAC
Product nameEasyPact CVS
Mounting modeFixed
Trip unit nameTM-D
Protection typeOverload protection (thermal) · Short-circuit protection (magnetic)
Connection pitch45 mm
Mounting supportBackplate
Neutral positionLeft
Range of productEasyPact CVS400...630
Trip unit rating400 A at 40 °C
Device short nameCVS400N
Network frequency50/60 Hz
Poles description4P
Upside connectionFront
Compatibility codeCVS400
Device applicationDistribution
[In] rated current400 A at 40 °C
Downside connectionFront
Trip unit technologyThermal-magnetic
Utilisation categoryCategory A
Electrical durability6000 cycles 415 V In conforming to IEC 60947-2
Mechanical durability15000 cycles
Breaking capacity codeN
Connections - terminalsScrew connection
[Icu] Breaking capacity70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 · 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 · 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Product or component typeCircuit breaker
Contact position indicatorYes
Neutral protection settingNo protection (3D)
Protected poles description3D
Long time delay adjustment typeFixed
Long time pick-up adjustment range0.7...1 x In
Thermal protection adjustment range280…400 A
Long time pick-up adjustment type IrAdjustable
[Ics] rated service breaking capacity70 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 · 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 · 32 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Earth leakage protection (Vigi add on)Without
Instantaneous pick-up adjustment range5...10 x In
[Uimp] rated impulse withstand voltage8 kV conforming to EN/IEC 60947-2
Instantaneous pick-up adjustment type IiAdjustable
Ratings as published by Schneider (se.com; se.com, Icu at 380/415 V). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.