🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider EasyPact CVS400F MCCB · 3P · 400 A · 36 kA · ETS 2.3 · LV540505LV540505↓ 40% off1 / 5
BrandSchneider
CategorySwitchgear
Specification3P · 400 A · 36 kA · ETS 2.3
Brand SKULV540505
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider EasyPact CVS400F MCCB · 3P · 400 A · 36 kA · ETS 2.3 · LV540505

Rating: 400 A
Poles: 3P
$779.59/pc-40%
$1,299.31
Wholesale · 15+ units
$740.61 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$779.59 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCCB
TP
400 A
-
36 kA
$779.59 /pc
Viewing above ↑
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $740.61/pc on this product, applied automatically

This device is a rated current 400A circuit breaker from EasyPact CVS400F. The rated breaking capacity(Ics) is 36kA at 415VAC,and complete range with Ics=100%Icu. The version of breaker is 3poles frame with detection on 3poles, also accompanied ETS 2.3 trip unit for electronic protection. It is conformed to standard IEC60947-2 for circuit breakers part. This device is certified for operation in pollution degree III environment as defined IEC60947-1& IEC60664-1, and respected for RoHs requirement as european environment directive EC/2002/95. It can be mounted by blackplate or Din rail,also through the door of class II switchboard without downgrading switchboard insulation. The front of toggle offers IP40 protection, but when it is equiped extended rotary handle inside the switchboard, additional IP54 protection degree for extended rotary handle. This series have slots for electrical auxiliaries(MN/MX/OF/SD),depending on the type of trip unit if rotary handle installed. The fixed dimension is 140mm width,255mm height,110mm depth.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider EasyPact CVS400F MCCB · 3P · 400 A · 36 kA · ETS 2.3 · LV540505 · LV540505
Poles3P (TP)
Rated current400 A
Breaking capacity36 kA
Ingress protectionIP40
Reference standardEN 60947-2
Net weight4.7 kg
Device typeMiniature circuit breaker (MCB)
Current rating400 A
BrandSchneider
Brand SKULV540505
ELINEFRK4G9P7R
Sold asPer pc
Depth110 mm
RangeEasyPact
Width140 mm
Control typeToggle
Network typeAC
Product nameEasyPact CVS
Mounting modeFixed
Thermal memoryYes
Trip unit nameETS 2.3
Protection typeInstantaneous short-circuit protection · Overload protection (long time) · Short time short-circuit protection
Connection pitch45 mm
Mounting supportBackplate
Range of productEasyPact CVS400...630
Trip unit rating400 A at 40 °C
Device short nameCVS400F
Network frequency50/60 Hz
Poles description3P
Upside connectionFront
Compatibility codeCVS400
Device applicationDistribution
[In] rated current400 A at 40 °C
Downside connectionFront
Trip unit technologyElectronic
Utilisation categoryCategory A
Electrical durability6000 cycles 415 V In conforming to IEC 60947-2
Mechanical durability15000 cycles
Breaking capacity codeF
Connections - terminalsScrew connection
[Icu] Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 · 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 · 30 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Product or component typeCircuit breaker
Contact position indicatorYes
Protected poles description3D
Trip unit protection functionsLSoI
Long time delay adjustment typeFixed
Short-time delay adjustment typeFixed
Long time pick-up adjustment range160…400 A
Long time pick-up adjustment type IrAdjustable 9 settings
[Ics] rated service breaking capacity40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 · 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 · 23 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
[tr] long-time delay adjustment range5.5 s at 7.2 x Ir · 8 s at 6 x Ir · 200 s at 1.5 x Ir
Earth leakage protection (Vigi add on)Without
Instantaneous pick-up adjustment range11 x In
Short-time pick-up adjustment type IsdAdjustable 9 settings
[Uimp] rated impulse withstand voltage8 kV conforming to EN/IEC 60947-2
Instantaneous pick-up adjustment type IiFixed
[Isd] short-time pick-up adjustment range1.5...10 x Ir
Ratings as published by Schneider (se.com; se.com, Icu at 380/415 V). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

What breaking capacity does this MCCB have?

This MCCB has a breaking capacity of 40 kA. It must be higher than the prospective short-circuit current at the point of installation, which depends mainly on the transformer size and cable length from it.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.

No reviews yet